TFT-Touch Ration Filling Controller With 4-Scale For Liquit Fillingweigher
Main Features:
- Suitable for Liquid/Gas/Powder Ration Fillingweigher [4-Scale].
- Optional filling modes: Fill on Drum’s Top / Fill on Drum’s Bottom / Step-fill from Drum’s Bottom.
- EMC design with high anti-jamming capability, suitable for industrial environment.
- Cortex-A8 CPU with 600MHz Clock, 128M RAM and 128M Flash.
- 7”/10.2” Ultralight and ultrathin TFT touch screen with embedded weighing/control module.
- Loadcell Interface
- Max. Connection Quantity: 16 Loadcells (350Ω).
- 24-bit High-precision and high-speed ∑-△A/D conversion module with 1/1,000,000 internal resolution and sampling frequency 800Hz.
- Special anti-vibration digital filtering algorithm for ensuring the weighing stability and accuracy when there is strong vibration on the load receptor, and the rapid response capability when the weight signal changes.
- 7 Definable normally open switch inputs [DI] and 12/18 definable normally open transistor switch outputs [DO].
- Optional ‘Bulk/Medium/Dribble Fill’ DOs for filling control. Optional Continuous and Jogging Dribble Fill Methods.
- 4 Optional&definable analog signal AO[0~10V] for weight signal output or ‘Bulk/Medium /Dribble Fill’ control.
- Digital Communication Interface
- COM1[RS232]&COM2[RS485] for connecting Host IPC/PLC and LED Remote Display.
- COM[RS232] for connecting RS232 Serial Printer.
- USB1 for connecting USB mouse, downloading HMI software from U-disk and copying data to U-disk.
- LAN: Optional Ethernet port.
- Manual Screen-locking/Screen-unlocking, Auto Screen-locking, Digital Setting&Calibration and I/O Testing functions available.
- Zero Upon Power Up, Zero Auto-tracking, Manual/Auto Zero and Zero Calibration available.
- Load Calibration function available.
- 50 Recipes for filling control.
- Optional ‘Auto Correct Inflight’ function.
- Optional ‘Pause for Tolerance Alarm’ and ‘Auto Dribble Re-fill’ functions.
- ‘Batch Target Finished’ alarm function available.
- The Batch Records can be printed automatically.
- Historical Batch Records, Totalizing Reports and Recipes can be queried and printed.
- With the multitasking mode, the weighing&control process will not be interrupted by parameter setting and the other operations.
Main Features
- EMC design with high anti-jam for industrial environment.
- DC24V power input with reverse polarity protection.
- Cortex-A8 CPU with 600MHz Clock, 128M Flash.
- 7” [800×480] or 10.2” [1024×600] TFT touch panel.
- 24-bit ∑-△ADC with internal resolution 1/1,000,000.
- High sampling frequency 800Hz.
- Special Anti-vibration Digital Filtering Algorithm for precise weighing, stable display and rapid response.
- Auto Zero Tracking.
- Fall Value Auto Correction.
- Auto Pause for Deviation Alarm.
- Auto Re-fill for Negative Deviation Alarm.
- Target Batch Count & Target Batch Weight Control.
- Filling Gun Impacting Drum Alarm.
- 3-speed[high/medium/low] filling control by DOs or AOs.
- Definable DI/DO/AO/COM[Communication Port].
- Recipe Number: 100.
Button Operation
Name | Operation | State Indicator | Authorization |
【Auto】 | Auto / Manual [Emergency Stop] switch. | Green: Auto state. Grey: Manual state. | All Users |
【Start】 | Start. | Green: Running state. Grey: Stop state. |
【Stop】 | Stop [Valid at Auto-running state]. | |
【Re-run】 | Clear Alarm & Recover Running. | |
【E-stop】 | Emergency Stop. | |
【Alarm】 | Alarm Query / Clear Alarm. ‘Auto/Pause’ state: Recover Running after alarms cleared. | Red: Alarm state. |
【Print】 | Report Print. | Green: Auto Print is allowed. |
【Lock】 | Screen-locking: Locking/unlocking the operating buttons of main user interface. Auto Screen-locking: Refer to parameter [901]. | Flashing Red: Locked. Grey: Unlocked. |
【Menu】 | Enter Main Menu. | |
【User】 | User Login. Display: Operator / Engineer / Admin. | |
【Lower】 | Manual Lower Filling Gun. | Flashing Green: Filling Gun is moving down. |
【Lift】 | Manual Lift Filling Gun. | Flashing Red: Filling Gun is moving up. |
【Bulk】 | Manual Start/Stop Bulk Fill. | Green: Working state. |
【Med】 | Manual Start/Stop Medium Fill. |
【Drip】 | Manual Start/Stop Dribble Fill. |
【Zero】 | Manual Zero [No Power-down Protection]. | Flashing Red. |
【Tare】 | Manual Tare [No Power-down Protection]. | Flashing Red. |
【Clear】 | Clear Screen: Clear the display values of Filling Weight, Totalized Weight and Batch Count. | | Engineer Administrator |

System Diagram