1-Scale TFT-Touch Digital Weight Indicator For Single-weighing-hopper Ration Packing Scale
Main Features:
- Suitable for Ration Packing Scale with optional Hopper-weighing Mode, Bag-weighing Mode and Loss-in-weight Mode.
- EMC design with high anti-jamming capability, suitable for industrial environment.
- Cortex-A8 CPU with 600MHz Clock, 128M RAM and 128M Flash.
- 7”/10.2” Ultralight and ultrathin TFT touch screen with embedded weighing/control module.
- Loadcell Interface
- Max. Connection Quantity: 16 Loadcells (350Ω).
- 24-bit High-precision and high-speed ∑-△A/D conversion module with 1/1,000,000 internal resolution and sampling frequency 800Hz.
- Special anti-vibration digital filtering algorithm for ensuring the weighing stability and accuracy when there is strong vibration on the load receptor, and the rapid response capability when the weight signal changes.
- 9 Definable normally open switch inputs [DI] and 18 definable normally open transistor switch outputs [DO].
- Optional ‘High/Medium/Low Speed Feed’ DOs for feeding control. Optional Low-speed Feeding Modes: Continuous Feeding Mode and Inching Feeding Mode.
- 2 Definable analog signal AOs[0~10V] for weight signal output or ‘High/Medium/Low Speed Feed’ control.
- Digital Communication Interface
- COM1[RS232]&COM2[RS485] for connecting Host IPC/PLC and LED Remote Display.
- COM[RS232] for connecting RS232 Serial Printer.
- USB1 for connecting USB mouse, downloading HMI software from U-disk and copying data to U-disk.
- Manual Screen-locking/Screen-unlocking, Auto Screen-locking, Digital Setting&Calibration and I/O Testing functions available.
- Initial Zero Adjustment after Power-on, Auto Zero Tracking, Zero Fine Adjustment and Zero Calibration functions available.
- Load Calibration and Loss Calibration functions available.
- 10 Recipes for packing control.
- Optional ‘Fall Value Auto Correction’ function.
- Optional ‘Auto Pause for Deviation Alarm’ and ‘Auto Re-feed’ functions.
- Optional ‘Target Batch Control’ function [With Target Batch Count or Target Batch Weight finished, the packing process will stop automatically].
- The Batch Records can be printed automatically.
- Historical Batch Records, Totalizing Reports and Recipes can be queried and printed.
With the multitasking mode, the weighing&control process will not be interrupted by parameter setting and the other operations.
Pictures



Button Operation
Name | Operation | State Indicator | Authorization |
【Auto】 | Auto / Manual [Emergency Stop] switch. | Green: Auto state. Grey: Manual state. | All Users |
【Start】 | Start. | Green: Running state. Grey: Stop state. |
【Re-run】 | Clear Alarm & Recover Running. | |
【Last】 | Last Batch [Normal Stop]. Stop after the present batch finished. | Flashing Red. |
【E-Stop】 | Emergency Stop. | |
【Alarm】 | Alarm Query / Clear Alarm. ‘Auto/Pause’ state: Recover Running after clearing alarm. | Red: Alarm state. |
【Print】 | Report Print: - [ Auto Print]: Print Batch Records.
- [Total]: Print Totalizing Report.
- [Recipe]: Print Working Recipe.
| |
【Lock】 | Screen-locking: Locking/unlocking the operating buttons of main display interface. Auto Screen-locking: Refer to parameter [901]. | Flashing Red: Locked. Grey: Unlocked. |
【Menu】 | Enter Main Menu. | |
【User】 | User Login. Display: Operator / Engineer / Admin. | |
【Zero】 | Zero Fine Adjustment [No Power-down Protection]. | Flashing green. |
【Bag】 | Bag-clamp/release Request. | Green: Bag-clamping state. Grey: Bag-releasing state. |
【High】 | Manual Start/Stop High-speed Feeding. | Green: Working state. |
【Med】 | Manual Start/Stop Medium-Speed Feeding. |
【Low】 | Manual Start/Stop Low-speed Feeding. |
【Dump】 | Manual Start/Stop Dumping. |
【Clear】 | Clear Screen: Clear the display values of Feeding Weight, Totalized Weight, Batch Count and Packing Speed. | | Engineer Administrator |
Outline Size

Terminal Diagram