TFT Touch Display Filling Controller Auto Zero Tracking With Load Cell
Main Features:
Technical Specification:
Power Supply | DC24V±20%,Max.10w. |
Display | HMI |
Sampling Frequency | 600Hz |
A/D Convert | 24-bit |
LAN | Optional Ethernet |
USB1 | Connect mouse, software download, data backup |
Max. Connection number of Loadcell | 16Loadcells (350Ω) |
DI | 9 Normally Open Switch Inputs |
DO | 18 Normally Open Transistor Switch Outputs |
AO | 2Analog Signal Output: 4~20mA. |
Operating Temperature | -25℃~+45℃ |
Verification Accuracy | 0.02% |
Filling Accuracy | 0.2%~0.5% |
Main Operation Interface
Name | Operation | State Indicator | Authorization |
【Auto】 | Auto / Manual [Emergency Stop] switch. | Green: Auto state. Grey: Manual state. | All Users |
【Start】 | Start. | Green: Running state. Grey: Stop state. | |
【Stop】 | Stop [Valid at Auto-running state]. | ||
【Re-run】 | Clear Alarm & Recover Running. | ||
【E-stop】 | Emergency Stop. | ||
【Alarm】 | Alarm Query / Clear Alarm. ‘Auto/Pause’ state: Recover Running after clearing alarm. | Red: Alarm state. | |
【Print】 | Report Print. | Green: Auto Print is allowed. | |
【Lock】 | Screen-locking: Locking/unlocking the operating buttons of main display interface. Auto Screen-locking: Refer to parameter [901]. | Flashing Red: Locked. Grey: Unlocked. | |
【Menu】 | Enter Main Menu. | ||
【User】 | User Login. Display: Operator / Engineer / Admin. | ||
【Lower】 | Manual Lower Filling Gun. | Flashing Green: Filling Gun is moving down. | |
【Lift】 | Manual Lift Filling Gun. | Flashing Red: Filling Gun is moving up. | |
【High】 | Manual Start/Stop High-speed filling. | Green: Working state. | |
【Med】 | Manual Start/Stop Medium-speed Filling. | ||
【Low】 | Manual Start/Stop Low-speed Filling. | ||
【Zero】 | Zero Fine Adjustment. [No Power-down Protection] | Flashing Red. | |
【Tare】 | Manual Tare. [No Power-down Protection] | Flashing Red. | |
【Clear】 | Clear Screen: Clear the display values of Filling Weight, Totalized Weight and Batch Count. | Engineer Administrator |
Data Display & Quick Setting
Name | Description | Authorization |
[NET] | Net Weight [Weight Unit]. | |
[FIL] | Filling Process Ended. | |
[GROSS] | Gross Weight. | |
[HIGH] | Gross Weight Upper Limit Alarm. | |
[OVLD] | Overload Alarm. | |
[PCS] | Batch Count. | |
[FINAL] | Final Filling Weight. | |
[▲]/[HI] | Positive Deviation Alarm and ‘Deviation & Limit Set’. | Administrator |
[▼]/[LO] | Negative Deviation Alarm and ‘Deviation & Limit Set’. | |
[TOT] | Totalized Weight. | |
[Date&Time] | Date&Time. | |
[RUN] | Auto Running state. | |
[PAUSE] | Pause state. | |
[DRUM] | DI switch ‘Empty Drum Ready’ turned on. | |
[UP] | Filling Gun Lift in Place. | |
[DOWN] | Filling Gun Lowered in Place. | |
[HIT] | Filling Gun Impacting Drum Alarm. | |
[ZERO] | Gross Weight ≤ Non-load Zero Range. | |
[STAB] | Weight is stable. | |
[FIN] | Target Batch [Count/Weight] Finished. | |
[Highest Filling Position ] | DI switch ‘Highest Step-filling Position Limit’ turned on. | |
[RECIPE] | ‘Working Recipe No.’ Selection. | All Users |
Recipe Parameter Setting. | Engineer | |
[TARGET] | ‘Target Value’ Setting. | All Users |
[HIGH] | ‘SP1 Lead Value for High-speed Filling’ Setting. | Engineer |
‘DO Filling's Mode’ Parameter Setting. | Administrator | |
[MED] | ‘SP2 Lead Value for Medium-speed Filling’ Setting. | Engineer |
‘DO Filling's Mode’ Parameter Setting. | Administrator | |
[FALL] | ‘SP3 Fall Value for Low-speed Filling’ Setting. | Engineer |
‘Fall Value Auto Correction’ Parameter Setting.
| Administrator | |
[MODE] | APP1 Fill on Top / APP2 Fill on Bottom / APP3 Step-fill from Bottom. Refer to Parameter [300] ‘Application Mode’. | |
[BAT. CNT] | ‘Target Batch Count’ Setting. | All Users |
[BAT. WT] | ‘Target Batch Weight’ Setting. | |
[Label Print Information] | Label title, No., Name and Checker Setting. |
TFT-Touch Raiton Filling Controller For Filling Liquid, Gas & Powder Materials
Outline Size
Installation Mode
Terminal Diagram