Button Operation
Name | Operation | State Indicator | Authorization |
【Auto】 | Auto / Manual [Emergency Stop] switch. | Green: Auto state. Grey: Manual state. | All Users |
【Start】 | Start. | Green: Running state. Grey: Stop state. | |
【Stop】 | Stop [Valid at Auto-running state]. | ||
【Re-run】 | Clear Alarm & Recover Running. | ||
【E-stop】 | Emergency Stop. | ||
【Alarm】 | Alarm Query / Clear Alarm. ‘Auto/Pause’ state: Recover Running after alarms cleared. | Red: Alarm state. | |
【Print】 | Report Print. | Green: Auto Print is allowed. | |
【Lock】 | Screen-locking: Locking/unlocking the operating buttons of main user interface. Auto Screen-locking: Refer to parameter [901]. | Flashing Red: Locked. Grey: Unlocked. | |
【Menu】 | Enter Main Menu. | ||
【User】 | User Login. Display: Operator / Engineer / Admin. | ||
【Lower】 | Manual Lower Filling Gun. | Flashing Green: Filling Gun is moving down. | |
【Lift】 | Manual Lift Filling Gun. | Flashing Red: Filling Gun is moving up. | |
【Bulk】 | Manual Start/Stop Bulk Fill. | Green: Working state. | |
【Med】 | Manual Start/Stop Medium Fill. | ||
【Drip】 | Manual Start/Stop Dribble Fill. | ||
【Zero】 | Manual Zero [No Power-down Protection]. | Flashing Red. | |
【Tare】 | Manual Tare [No Power-down Protection]. | Flashing Red. | |
【Clear】 | Clear Screen: Clear the display values of Filling Weight, Totalized Weight and Batch Count. | Engineer Administrator |
Technical Specifications
Power Supply: DC24V±20%, Max. 10W.
Loadcell Excitation Voltage/Current: DC5V/250mA.
16 Loadcells[350Ω] connectable.
Weighing Signal Input Range: 0~12.5mV.
9 Normally Open Switch Inputs [DI].
18 Normally Open Transistor Outputs [DO]: DC24V, 500mA.
2 Analog Signal Outputs [AO]: 0~10V, Max.50mA.
COM&COM1: RS232; COM2: RS485.
USB1: Connect mouse, software download, data backup.
LAN: Optional Ethernet.
Outline Size [W×H×D]
7”: 226.5 × 163 × 36 mm.
10.2”: 274 × 193 × 40 mm.
Panel Cut-out Size [W×H]
7”: 215 × 152 mm.
10.2”: 261 × 180 mm.
Operating Temperature: -25℃~+45℃.
Protection Level of Front Panel: IP65.
Accuracy Grade: III.
Verification Accuracy: 0.02%.
Static Weighing Accuracy: 0.2%~0.5%