LCD Display TFT Batching Weighing Controller With Panel Mounted Box and USB port Connected
Main Features:
Technical Specification:
Power Supply | DC24V±20%,Max.10w. |
Display | HMI |
Sampling Frequency | 800Hz |
A/D Convert | 24-bit |
LAN | Optional Ethernet |
USB1 | Connect mouse, software download, data backup |
Max. Connection number of Loadcell | 8 Loadcells (350Ω) |
DI | 7 Normally Open Switch Inputs |
DO | 18 Normally Open Transistor Switch Outputs |
AO4 | Analog Signal Output: 4~20mA. |
Operating Temperature | -25℃~+45℃ |
Verification Accuracy | 0.02% |
Packing Accuracy | 0.2%~0.5% |
Name | Operation | State Indicator | Authorization |
【Auto】 | Auto / Manual [Emergency Stop] switch. | Green: Auto state. Grey: Manual state. | All Users |
【Start】 | Start. | Green: Running state. Grey: Stop state. | |
【Re-run】 | Clear Alarm & Recover Running. | ||
【Stop】 | 【E-stop】: Emergency Stop. | ||
【Last】Last Batch [Normal Stop]. Stop after the present batch finished. | Flashing Red. | ||
【E-stop】 | Emergency Stop. | ||
【Alarm】 | Alarm Query / Clear Alarm. ‘Auto/Pause’ state: Recover Running after clearing alarm. | Red: Alarm state. | |
【Bag】 | Bag-clamp/release Request. | Green: Bag-clamping state. Grey: Bag-releasing state. | |
【Print】 | Report Print:
| ||
【Lock】 | Screen-locking: Locking/unlocking the operating buttons of main display interface. Auto Screen-locking: Refer to parameter [901]. | Flashing Red: Locked. Grey: Unlocked. | |
【Menu】 | Enter Main Menu. | ||
【User】 | User Login. Display: Operator / Engineer / Admin. | ||
【Inhibit】 | Inhibit/Allow Switch. | Red: The lane is OFF. Grey: The lane is ON. | |
【Zero】 | Zero Fine Adjustment [No Power-down Protection]. | Flashing green. | |
【High】 | Manual Start/Stop High-speed Feeding. | Green: Working state. | |
【Med】 | Manual Start/Stop Medium-speed Feeding. | ||
【Low】 | Manual Start/Stop Low-speed Feeding. | ||
【Dump】 | Manual Start/Stop Dumping. | ||
【Clear】 | Clear Screen: Clear the display values of Feeding Weight, Totalized Weight, Batch Count and Packing Speed. | Engineer Administrator |
Data Display & Quick Setting
Name | Description | Authorization |
Biggest Digits | Real-time Weight [Weight Unit]. | |
[HI] | Weight Upper Limit Alarm. | |
[OL] | Overload Alarm. | |
Bigger Digits | Final Feeding Weight. | |
[▲]/[HI] | Positive Deviation Alarm. | |
[▼]/[LO] | Negative Deviation Alarm. | |
[Date&Time] | Date&Time. | |
[RUN] | Auto Running state. | |
[PAUSE] | Pause state. | |
[P_SW] | DI switch ‘Dumping Gate Closed in Place’ turned on. | |
[ZERO] | Weight ≤ Non-load Zero Range. | |
[STAB] | Weight is stable. | |
[Feeder] | Feeder is working. | |
[FED] | Feeding Ended. | |
[FIN] | Target Batch [Count/Weight] Finished. | |
[LABEL]/[GAS]/ [SEW]/[CUT] | In the process of ‘Labeling on Bag’ / ‘Filling Gas into Bag’ / Bag-sewing / Thread-cutting. | |
[SPLY] | In the process of ‘Supplying Material into Feeding Hopper’. | |
[Au-supply DI] | ‘Material Auto-supply Permit’ DI truns ON/OFF. | |
[RECIPE] | ‘Working Recipe’ Setting. | All Users |
[TARGET] | ‘Target Value’ Setting. | |
[SP1] | SP1 Lead Value for High-speed Feeding. | |
[SP2] | SP2 Lead Value for Medium-speed Feeding. | |
[FALL] | SP3 Fall Value for Low-speed Feeding. | |
| ||
[BAT. CNT] | Target Batch Count. | |
[CYCLES] | Batch Count. | |
[BAT. WT] | Target Batch Weight. | |
[TOTAL] | Totalized Weight. | |
[CPM] | Packing Speed [Cycles/min]. | |
[Packing Mode] |
Refer to Parameter [303] ‘Packing Mode’. |
4-Scale Weighing Controller For Respective / Combination Packing With 4-weighing-hopper&1/4-bag and Multi-hopper packing / Single-hopper packing
Outline Size:
Installation Mode
Terminal Diagram
Software Function