Belt Loss-in-weight Weighfeeder Controller For Conveyor Weighing System
Main Features
Operation Interface Diagram
Keypad Operation
If there is not any keypad operation in one minute and it’s not in the processes of ‘F2 Calibration’ & ‘F6 Factory Adj.’, the controller will return to ‘Main Display Interface’ automatically.
Menu Operation | |
Key Name | Description |
【MENU】 | Enter Main Menu. Exit. |
【ENT】 | Enter/Save. |
【▲】 | Cursor shifts up or left. Display the previous interface or option. |
【▼】 | Cursor shifts down or right. Display the next interface or option. |
【0~9】 | Digit Input. |
Quick Operation | |
【LOCK】 |
|
【F1】 | Return to the initial display interface. |
【SET】 | Flow Set Value Setting. |
【ADJ-】 | Control Current -1mA. |
【ADJ+】 | Control Current +1mA. |
【AUTO】 | ‘Manual/Auto’ Control Mode Selection. |
【EXT】 | ‘Internal/External’ Flow Set Mode Selection. |
【ZERO】 | Zero Calibration. |
【CAL】 | Dynamic Span Calibration. |
【CLS】 | Clear Screen: Clear display value of Totalized Weight. |
【REC】 | Query and print Weight Record. |
【PRINT】 | Print. |
State Indication
LED Lamp | Description |
[RUN] | ON: Weighing state. |
[AUTO] | Feeding control mode: |
[EXT] | Flow Set Mode: |
[ALARM] | Alarm. |
[LOCK] | ON: Key-locked. |
Installation
Ration Flow Auto-Feeding System
Main Applications: