Industrial High Resolution Touch Screen Coffee Packing Weighing Controller BST106-M10(AL)
Outline Size
Button Operation
Name | Operation | State Indicator | Authorization |
【Auto】 | Auto / Manual [Emergency Stop] switch. | Green: Auto state. Grey: Manual state. | All Users |
【Start】 | Start. | Green: Running state. Grey: Stop state. | |
【Re-run】 | Clear Alarm & Recover Running. | ||
【Stop】 | Normal Stop [Last Batch]. Stop after the present batch finished. | Flashing Red. | |
【E-Stop】 | Emergency Stop. | ||
【Alarm】 | Alarm Query / Clear Alarm. ‘Auto/Pause’ state: Recover Running after alarms cleared. | Red: Alarm state. | |
【Print】 | Report Print:
| ||
【Lock】 | Screen-locking: Locking/unlocking the operating buttons of main user interface. Auto Screen-locking: Refer to parameter [901]. | Flashing Red: Locked. Grey: Unlocked. | |
【Menu】 | Enter Main Menu. | ||
【User】 | User Login. Display: Operator / Engineer / Admin. | ||
【Zero】 | Manual Zero [No Power-down Protection]. | Flashing green. | |
【Bag】 | Bag-clamp/release Request. | Green: Bag-clamping state. Grey: Bag-releasing state. | |
【Bulk】 | Manual Start/Stop Bulk Feed. | Green: Working state. | |
【Med】 | Manual Start/Stop Medium Feed. | ||
【Drip】 | Manual Start/Stop Dribble Feed. | ||
【Dump】 | Manual Start/Stop Dumping. | ||
【Mat.】 | Manual Start/Stop Supplying Materials into Feeding Bin. | Flashing green. | |
【Clear】 | Clear Screen: Clear the display values of Feeding Weight, Totalized Weight, Batch Count and Cycle Speed. | Engineer Administrator |
Error Messages
Message | Alarm Cause | Solution |
RAM Fault | The chip RAM is damaged. | Replace the chip RAM. |
EEPROM Fault | The chip EEPROM is damaged. | Replace the chip EEPROM. |
Parameter Error | The chip EEPROM is damaged. | Replace the chip EEPROM. |
Weighing Signal Error | Weighing signal reversed or not connected. | Connect the loadcell correctly. |
ADC Fault | The chip ADC is damaged. | Replace the ADC module. |
Over ADC Range | Weighing signal exceeds A/D conversion range. | 1. Check if the loadcell is connected. 2. Check if the capacity of loadcell is too small. 3. Check if the loading weight is too big. |
Overload Alarm | Weight > (Scale Capacity + 9 × Scale Division). | 1. Check if the set value of parameter [102] ‘Scale Capacity’ is reasonable. 2. Check if the loadcell is connected. 3. Check if the capacity of loadcell is too small. 4. Check if the loading weight is too big. |
Internal Data-bus Fault | Please contact manufacturer. |