Features
Specification
Maximum capacity (Emax) | t | 1, 2, 3, 5, 7.5 |
Rated output (Cn) | mV/V | 2.0 ± 0.01 |
Accuracy | ±%FS | 0.05 |
Max. number of intervals (nLC) | - | 3000 |
Creep (30 minutes) | ±%FS | 0.03 |
Zero balance | ±%FS | 1 |
Temperature effect on zero balance (TCO) | ±%FS/10°C | 0.03 |
Temperature effect on sensitivity (TC Span) | ±%FS/10°C | 0.03 |
Safe overload | %FS | 150 |
Ultimate overload | %FS | 200 |
Nominal temperature range | °C | -10 ... + 40 |
Operating temperature range | °C | - 30 ... + 70 |
Input impedance | Ω | 750 ± 10 |
Output impedance | Ω | 703 ± 2 |
Insulation impedance | MΩ | ≥ 5000 |
Recommended excitation | V DC/AC | 10 -12 |
Excitation maximum | V DC/AC | 15 |
Material | - | Alloy steel |
Protection class | - | IP68 |
Cable | - | Length: 3m or customize special length to order; Diameter: Φ 5mm |
Wiring
The load cell is provided with a shielded 4 or 6 conductor cable. The shield will be connected or not connected to the load cell according to customer’s preference.
Dimension
Dimension unit:mm