Features
50-200kg 400 x 400mm
300-500kg 600 x 800mm
750-2000kg 1200 x 1200mm
Specification
Maximum capacity (Emax) | kg | 50, 100, 200, 300, 500, 750, 1000, 2000 |
Rated output (Cn) | mV/V | 2,0 ± 0,2 |
Accuracy | ±%FS | 0.02 |
Max. number of intervals (nLC) | - | 3000 |
Creep (30 minutes) | ±ppm | 166 |
Zero balance | ±%FS | 3 |
Temperature effect on zero balance (TCO) | ±ppm/°C | 17.5 |
Temperature effect on sensitivity (TC Span) | ±ppm/°C | 17.5 (+20~+40°C); 11.7(-10~+20°C) |
Safe overload | %FS | 150 |
Ultimate overload | %FS | 300 |
Nominal temperature range | °C | -10 ... + 40 |
Operating temperature range | °C | - 20 ... + 50 |
Input impedance | Ω | 404 ± 15 |
Output impedance | Ω | 350 ± 3 |
Insulation impedance | MΩ | ≥ 2000 |
Recommended excitation | V DC/AC | 10 |
Excitation maximum | V DC/AC | 15 |
Material | - | Aluminium |
Protection class | - | IP65 |
Cable | - | Length: 3m or customize special length to order; Diameter: Φ 5mm |
Wiring
The load cell is provided with a shielded 4 or 6 conductor cable. The shield will be connected or not connected to the load cell according to customer’s preference.
Dimension