Features
Specification
Maximum capacity (Emax) | kg | 100, 150, 200, 250, 300, 500, 750, 1000 | 1200, 1500, 2000, 3000, 5000 | |
Rated output (Cn) | mV/V | 2,0 ± 0,002 | ||
Accuracy | ±%FS | 0.03 | ||
Max. number of intervals (nLC) | - | 3000 | ||
Creep (30 minutes) | ±%FS | 0.02 | ||
Zero balance | ±%FS | 1 | ||
Temperature effect on zero balance (TCO) | ±%FS/10°C | 0.02 | ||
Temperature effect on sensitivity (TC Span) | ±%FS/10°C | 0.02 | ||
Safe overload | %FS | 120 | ||
Ultimate overload | %FS | 150 | ||
Nominal temperature range | °C | -10 ... + 40 | ||
Operating temperature range | °C | - 30 ... + 70 | ||
Input impedance | Ω | 400 ± 20 | ||
Output impedance | Ω | 352 ± 3 | ||
Insulation impedance | MΩ | ≥ 5000 | ||
Recommended excitation | V DC/AC | 10 -12 | ||
Excitation maximum | V DC/AC | 15 | ||
Material | - | Alloy steel | ||
Protection class | - | IP65 | IP68 | |
Cable | - | Length: 5m; or customize special length to order; Diameter: Φ 5mm |
Wiring
The load cell is provided with a shielded 4 or 6 conductor cable. The shield will be connected or not connected to the load cell according to customer’s preference.
Dimension
100-1000kg:
1200-5000kg:
Accessories
No accessory is provided for standard shipment