22 Liter 400Watt Medical Ultrasonic Cleaner With 600W Heating Power
How Whale Cleen sonic Medical Ultrasonic Cleaner Works?
Ultrasonic cleaning uses high frequency sound waves to generate cavitation in the liquid. The resulting energetic bubble action penetrates blind holes, cracks, and recesses to thoroughly remove all traces of contamination adhering or embedded on the solid surface. Contaminants can include blood,tissue,body fluid,dust, dirt, oil, pigments, grease, polishing compounds, flux agents, soot, and more.
Detail Information Of Z-S08:
Model | Z-S08 |
Ultrasonic Frequency | 40,000 Hz |
Tank Material | Stainless Steel SUS304 |
Tank Capacity | 22 L |
Timer | 1-30minutes ,Digital timer |
Power Supply | AC 100 ~ 120V, 50 / 60Hz AC 220 ~ 240V, 50 / 60 Hz |
Ultrasonic Power | 500W |
Heating Power | 600 W , Digital Heating |
Tank Size | 500×300×150 mm ( L x W x H ) |
Unit Size | 530×325×285 mm ( L x W x H ) |
Package Size | 635×405×340mm( L x W x H ) |
Longest Gun You Can Clean | 480mm |
N.W. | 12.1kg |
G.W. | 15.6kg |
If this model is not suitable for you, please check other in below chart.
Model | Tank size | Unit size | Volume | Actual ultrasonic power | Rated ultrasonic power | Ultrasonic frequency | Heating power | Timer | Heating temperature |
LxWxH(mm) | LxWxH(mm) | (L) | (W) | (W) | (kHz) | (W) | (MIN) | (℃) | |
Z-S008 | 150x85x65 | 175x110x125 | 0.8 | 30 | 30 | 40 | no | 1-30 | no |
Z-S01 | 150x135×100 | 175x160x210 | 2 | 50 | 60 | 40 | 150 | 1-30 | 0-80 |
Z-S02 | 240x135x100 | 265x165x220 | 3.2 | 100 | 120 | 150 | |||
Z-S03 | 300x150x100 | 325x180x225 | 4.5 | 150 | 180 | 300 | |||
Z-S031 | 300x150x150 | 325x180x280 | 6.5 | 150 | 180 | 300 | |||
Z-S04 | 300x240x150 | 325x265x280 | 10.8 | 200 | 240 | 450 | |||
Z-S06 | 330x300x150 | 360x325x285 | 15 | 300 | 360 | 450 | |||
Z-S08 | 500x300x150 | 530x325×285 | 22 | 400 | 480 | 600 | |||
Z-S10 | 500x300x200 | 530x325x325 | 30 | 500 | 600 | 600 |
Customer's Feedback From USA:
Cleaning Steps For Surgical Instrument:
In all cases manufacturers’ instructions should be followed when using an ultrasonic cleaning process. These are representative steps.
Fill the ultrasonic cleaning tank with an approved medical instrument cleaning solution following dilution instructions provided. Turn the cleaner on to start the degassing process. This step removes entrained air in new solutions that interferes with the efficiency of cavitation and takes approximately 10 minutes.
In the meantime:
At the end of the cycle, remove the instruments from the ultrasonic cleaning bath and thoroughly rinse them to remove all traces of the cleaning solution. Deionized water rinses will avoid spotting. If the instruments are not to be immediately disinfected and sterilized be certain that they are thoroughly dried and protected. Part reassembly can occur after sterilization.
Procedures should be in place to guide the replacement of used ultrasonic cleaning solutions. In some instances it is recommended that solution be drained and tanks thoroughly cleaned and dried after each ultrasonic cleaning cycle. Most solutions available today are biodegradable, which facilitates disposal but local authorities should be consulted on proper practices.