CCS Approved Automatic Marine Fresh Water Generator For Water Purifier
(1) Usage: It is used for treating teh sewage on board, shipyard or dock (2) international standard: IMO resolution MEPC159(55), Annex IV of (MARPOL 73/78), MEPC. 2(VI)
(3) discharge standard: TSS ≤ 35mg/L, BOD5 ≤ 25mg/L, COD ≤ 125mg/L, Coliform ≤ 100PC/100ml, pH: 6~8.5
(4) Electricity: AC380V. 50Hz, 3Φ AC440V, 60Hz, 3Φ (the electricity can be changed in according to your requirment )
(5) Capacity: From 15 persons to 440 persons
(6) Certificate: EC, CCS
Description:
This mineral water plant includes raw water tank ,raw water pump,silica sand filter,active carbon filter,
ion exchanger,high pressure pump,precision filter, security filter ,reverse osmosis,Ozone generator sterilizer,UV, Mixing tower ,water pump, water storage tank.
water quality
a. The customer's requirement of the output water quality and output water capacity
b. The reliability of the design of the process
1) The system can change the water quality steadily
2) The easy operation and automatic operation
3) Investment and operation cost
4) The physical and chemical cleaning function of the system
5) The output water quality stability
6) The reliable on line monitor function
Parameters:
Model | LG-FSHB1 | LG-FSHB2 | LG-FSHB5 | LG-FSHB10 | |
Productm3/d | 1~1.5 | 2~3 | 5~6 | 10~11 | |
Freshwater flows(L/h) | 50~60 | 100~130 | 200~250 | 400~450 | |
Desalination rate% | ≥98 | ≥98 | ≥98 | ≥98 | |
Salt content of product water(mg/L) | ≤1000 | ≤1000 | ≤1000 | ≤1000 | |
Product water pressure(MPa) | 4~6.5 | 4~6.5 | 4~6.5 | 4~6.5 | |
Power consumption(kw) | 1.1 | 1.5 | 2.2 | 5.5 | |
Boosting inlet pressure(MPa) | 0.1~0.3 | 0.1~0.3 | 0.1~0.3 | 0.1~0.3 | |
Temperature of inlet water | 5~40 | 5~40 | 5~40 | 5~40 | |
Weight(kg) | 110 | 120 | 140 | 200 | |
Dimension | L(mm) | 580 | 580 | 650 | 800 |
W(mm) | 440 | 440 | 440 | 600 | |
H(mm) | 1600 | 1600 | 1600 | 1700 |