Carbon Steel Sewage Water Treatment Unit Automatic 15 Persons Capacity
Overview:
Marine Sewage Treatment Plant belongs to the key devices for prevention of pollution form ships in
seas and oceans according to the revised Annex IV of the International Convention of the Prevention of Pollution (MARPOL 73/78).This device is applicable to treat the sewage, which means human body wastes and the wastes from the toilets on vessels and which is also called “black water”, to meet the effluent standards of IMO. MEPC.159(55), and discharge the effluent overboard . This device is according to the resolution MEPC.159(55) enacted on 13 October 2006.The convention (MARPOL 73/78) provides that all STPs installed on board on or after 1 January 2010 should meet the resolution MEPC159(55).
Features:
(1) Usage: It is used for treating teh sewage on board, shipyard or dock (2) international standard: IMO resolution MEPC159(55), Annex IV of (MARPOL 73/78), MEPC. 2(VI)
(3) discharge standard: TSS ≤ 35mg/L, BOD5 ≤ 25mg/L, COD ≤ 125mg/L, Coliform ≤ 100PC/100ml, pH: 6~8.5
(4) Electricity: AC380V. 50Hz, 3Φ AC440V, 60Hz, 3Φ (the electricity can be changed in according to your requirment )
(5) Capacity: From 15 persons to 440 persons
(6) Certificate: EC, CCS
Description:
This plant is applicable to treat the sewage, which means human body wastes and the wastes from the toilets on vessels and which is also called "black water", to meet the effluent standards of IMO MEPC. 159(55), and discharge the effluent to overboard. It is also applicable to treat galley & shower drainage which is called "grey water" on condition that the "grey water" should be pretreated and should select a bigger capacity model to match with.
Parameters:
Model |
SWCM |
||||||||||||||||
6 |
10 |
15 |
20 |
25 |
30 |
40 |
50 |
60 |
80 |
100 |
150 |
200 |
250 |
300 |
|||
Load |
Average load |
490 |
840 |
1190 |
1540 |
1890 |
2310 |
3080 |
3780 |
4480 |
6020 |
7700 |
11200 |
14700 |
18200 |
23100 |
|
Peak load |
62 |
105 |
149 |
193 |
237 |
289 |
385 |
473 |
560 |
753 |
963 |
1400 |
1838 |
2275 |
2888 |
||
Organic load |
0.245 |
0.42 |
0.595 |
0.77 |
0.945 |
1.155 |
1.54 |
1.89 |
2.24 |
3.01 |
3.85 |
5.6 |
7.35 |
9.10 |
11.55 |
||
Rated capacity (P) |
6 |
10 |
15 |
20 |
25 |
30 |
40 |
50 |
60 |
80 |
100 |
150 |
200 |
250 |
300 |
||
Max capacity(P) |
7 |
12 |
17 |
22 |
27 |
33 |
44 |
54 |
64 |
86 |
110 |
160 |
210 |
260 |
330 |
||
Electricity |
AC 380V50Hz3φ/AC 44060Hz3φ |
||||||||||||||||
Power (KW) |
1.5 |
1.5 |
1.5 |
1.5 |
1.5 |
1.5 |
1.5 |
2.0 |
2.0 |
2.5 |
2.5 |
3.0 |
3.0 |
3.0 |
3.0 |