Specifications
Brand Name :
WINLEY
Model Number :
S-3000/25
Certification :
UL,cUL,CE,ISO
Place of Origin :
CHINA
MOQ :
1unit
Price :
$5000-$150000
Payment Terms :
T/T
Supply Ability :
1000set/month
Delivery Time :
30days
Packaging Details :
Plywood case
Type :
pad mounted,radial feed
Capacity :
3000 KVA
Primary Voltage :
24.94KV
Secondary Voltage :
4160Y/2400
Vector Group :
Dyn1
Cooling method :
ONAN
Insulation class :
A (105℃)
Standard :
ASNI/IEEE C57.12.00
Description

Three Phase Pad Mounted Transformer 3000Kva 24940V To 4160Y/2400 UL Certified

The three phase pad mounted transformers we produce have obtained UL certification, with capacities ranging from 30 to 5500kVA and voltages up to 34.5kV. Our products are exported to North America the Philippines and other places in large quantities.

Three Phase Pad Mounted Transformer 3000Kva 24940V To 4160Y/2400 UL Certified

Main data

Particulars Unit Specification Remark
Type ~ pad mounted,radial feed
Rated capacity kVA 3000
No. of Phase ~ 3
Primary voltage V 24940 delta
Primary termination ~ 25kV class Porcelain bushing live front
Secondary voltage V 4160Y/2400 Wye-N
Secondary connection ~ 5kV class Porcelain bushing live front
Tapping type ~ off-circuit tapping
Tapping range % ±2*2.5%
Cooling method ~ ONAN
Rated frequency Hz 60
Vector group ~ Dyn1
Insulation class ~ A (105℃)
Temperature rise K 65
Off-load loss W 2810 with 10% tolerance
On-load loss (85℃) W 25796
Impedance % 5.0~7.5
Winding material ~ Cu
Core material ~ silicon steel
Cooling material Mineral oil
Housing material ~ coated steel
Service condition ~ indoor or outdoor
Sea level M ≤1000
Standard ~ ASNI/IEEE C57.12.00

Standard Features


• 60 Hz operation.
• 65°C average winding rise.
• Radial & loop feed arrangements.
• Dead and live front type of HV terminals.
• HV BIL 45 – 150 kV (Dead Front) 200 kV (Live Front).
• LV BIL 30 – 60 kV.
• Three-point latching of low-voltage door.
• High-voltage door, which can be opened only after
the low-voltage door is opened.
• Rigid steel partition.
• Transformer tank welded from cover to base.
• Permanent nameplate.
• One-inch NPT pipe cap filling provision.
• ANSI tank ground pads.
• One-inch drain valve and sampler.
• Automatic pressure-relief valve (35 SCFM).
• Tap changer with (2) 2.5% full capacity taps above
and below nominal.
• One 10”x18” (or 14”x25”) hand hole in transformer
tank cover.
• Painted olive-green color (Munsell 7GY 3.29/1.5).
• Designed, manufactured and tested in accordance
with the latest ANSI standards

Technical drawings

Three Phase Pad Mounted Transformer 3000Kva 24940V To 4160Y/2400 UL Certified

Product structure

1)The transformer part and the control cabinet part of the United States variation, of which the transformer part is a fully sealed structure, and the insulating oil can be two types of high ignition point oil or ordinary oil.
2)The control cabinet is divided into a high-voltage room and a low-voltage room.
3)The high-voltage room is equipped with: high-voltage cable plug, lightning arrester, load switch operating handle, non-excitation tap switch handle, plug-in fuse, pressure release valve, thermometer, pressure gauge, oil Position gauges, oil filling plugs, oil drain valves, etc., load switches, off-excitation tap changers, plug-in fuses, etc. are all immersed in transformer oil together with the transformer core. The high-voltage cable and the transformer are connected by elbow cable connectors.
4)The low-voltage side can be installed with air circuit breakers, current transformers, as well as electric energy meters, ammeters and voltmeters, and output circuits and capacitance compensation devices can be configured according to user needs.

Specification

PRODUCT SPECIFICATION
Rated Power
(KVA)
High Voltage
(KV)
Low Voltage
(V)
No-load Loss
(W)
On-load Loss
(W)
Height
(mm)
Depth
(mm)
Width
(mm)
Weight
(kg)
75 34.5KV
4.160KV
12.47KV
13.2KV
13.8KV
24940GrdY/14400
1247Grdy/7200
4160GrdY/2400
or others
277V
347V
480V
600V
120/240V
208GrdY/120
415GrdY/240
480GrdY/277
600Y/347
180 1250 1430 910 1930 645
150 280 2200 1530 980 1510 989
300 480 3650 1680 1080 1660 1415
500 680 5100 1790 1160 1810 1905
750 980 7500 2030 1300 2030 2755
1000 1150 10300 1854 1549 1651 3235
1500 1640 14500 2150 1570 2210 5835
2000 2160 20645 2220 1600 2380 6430
2500 2680 23786 2330 1650 3070 8865
3000 3300 30300 2460 1850 3260 11300
3735 4125 37875 2680 2060 4080 14400

Applicable Standards


IEEE Std C 57.12.00 – Standard for Standard General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers.
IEEE Std C 57.12.28 – Pad-Mounted Equipment - Enclosure Integrity.
IEEE Std C 57.12.34 – Standard Requirements for Pad-Mounted, Compartmental-Type, Self-Cooled, Three-Phase Distribution Transformers
IEEE Std C 57.12.90– Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers and IEEE Guide for Short-Circuit Testing of Distribution and Power Transformers.
IEEE Std C 57.12.91 – Guide for Loading Mineral-Oil-Immersed Transformers.

Production process

Three Phase Pad Mounted Transformer 3000Kva 24940V To 4160Y/2400 UL Certified

Three Phase Pad Mounted Transformer 3000Kva 24940V To 4160Y/2400 UL Certified

UL /cUL Certification

Three Phase Pad Mounted Transformer 3000Kva 24940V To 4160Y/2400 UL Certified

FAQ

1. Q: Can I have a sample order?

A: Yes, we welcome sample order to test and check quality.

2. Q: What is the lead time?

A: Mass production time 15-25 days.

3. Q: How long is the warranty?

A: 24 monthes from B/L. If there are any accessory problems,just provide the photos of damaged accessory,then we will provide free service. According to the number of products,we will provide easily damaged accessories for free. we also can provide technical support if you need.

4. Q: Is OEM/ODM available?

A: Yes,it is! We are manufacturer with our own R&D team, we can customize products according to customer's drawing or requirements.

Customized services:

a. Customized color and special function.

b. Customized box.

c. Print customer's logo.

d. Your other ideas about product, we can help you design and put them into production. The above customized services must be confirmed before production.

5. Q: How to control the products quality?

A: Our company owns the core technology ,all kinds of products hold CE certificate. We have professional engineers. Workers are strictly required to make products according to the drawings. Each process has technical instructors.The QC supervisors will regularly inspect the production. We will do products performance tests during production, and comprehensive quality tests when the products is completed.

Send your message to this supplier
Send Now

Three Phase Pad Mounted Transformer 3000Kva 24940V To 4160Y/2400 UL Certified

Ask Latest Price
Watch Video
Brand Name :
WINLEY
Model Number :
S-3000/25
Certification :
UL,cUL,CE,ISO
Place of Origin :
CHINA
MOQ :
1unit
Price :
$5000-$150000
Contact Supplier
video
Three Phase Pad Mounted Transformer 3000Kva 24940V To 4160Y/2400 UL Certified
Three Phase Pad Mounted Transformer 3000Kva 24940V To 4160Y/2400 UL Certified
Three Phase Pad Mounted Transformer 3000Kva 24940V To 4160Y/2400 UL Certified
Three Phase Pad Mounted Transformer 3000Kva 24940V To 4160Y/2400 UL Certified
Three Phase Pad Mounted Transformer 3000Kva 24940V To 4160Y/2400 UL Certified

Xiamen Winley Electric Co.,Ltd

Verified Supplier
4 Years
fujian, xiamen
Since 2007
Business Type :
Manufacturer, Seller
Total Annual :
$15M-$20M
Employee Number :
50~70
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement