1/2'' ultra flexible coxial cable line for telecommunication
Item | Material | Diameter(MM) |
1. Inner Conductor | Naked copper or copper-clad aluminium conductor | 3.6 |
2. Insulator | EPO | 8.8 |
3. Outer Conductor | Threaded copper pipe | 12.1 |
4. Sheath | PE or LSZH flame-retardant polyolefine cable | 13.4 |
Electric Performance | |
Electric capacity(pF/m) | 80 |
Electric resistance(ohm) | 50 |
Transfer Rate(%) | 83 |
DC inner conductor resistance(Ω/km) | 2.85/1.78 |
DC outer conductor resistance(Ω/km) | 3.5 |
Attenuation Shield(dB) | >120 |
Peak Power(KW) | 19 |
Peak Voltage(KV) | 1.13 |
Insulation Resistance(MΩ.km) | >5000 |
Cut off frequency(GHz) | 12.5 |
Insulation voltage (KVrms) | 2.5 |
Sheath Spark(KVrms) | 5.0 |
Mechanical&Environmental Performance | |
Storage Temperature(℃) | -55 to +85 |
Installation Temperature(℃) | -20 to +60 |
Work Temperature(℃) | -55 to +85 |
Minimum bending radius(mm) | 50 |
Min repeated bending radius(mm) | 125 |
Tensile strength; (KG) | 110 |
ROHS Eco Friendly | Yes |
Attenuation and Mean Power (VSWR1.0,20℃) | ||
Frequency(MHz) | Mean Power (KW) | Attenuation(dB/m) |
100 | 3.03 | 3.22 |
200 | 2.11 | 4.65 |
450 | 1.37 | 7.20 |
800 | 1.00 | 9.86 |
900 | 0.94 | 10.56 |
1000 | 0.88 | 11.15 |
1500 | 0.70 | 13.80 |
1800 | 0.63 | 15.55 |
2000 | 0.59 | 16.40 |
2200 | 0.56 | 17.35 |
2400 | 0.53 | 18.10 |
2500 | 0.52 | 18.50 |
3000 | 0.48 | 20.90 |