110V 220V AC to 5V 12V 24V DC Output Variable Voltage Switch Mode Power Supplies
Application: Industrial, security monitoring, machine, equipment, LED billboard, medical treatment, electrical, communications, etc.
Feature:
1. Full range of input (Selectable by switch)
2. Over current, over voltage and short circuit protection
3. 100% full load test
4. Low price and reliable quality
5. Two years’ warranty
Technical specification
Input Voltage: 85-264V AC, 47-63Hz; 120-370V DC
Impact Current: Cold start current
DC Voltage Adjustable Scope: 10% of the rated output voltage
Overload Protection: 115% ~ 150% of current, automatic recovery
Over Voltage Protection: 115%-135% of output voltage
Start, Rising and Hold-up Time: 300ms, 50ms, 80ms
Withstanding Voltage: 1.5KV AC between input and output, 1.5KV AC between input and shell, 0.5KV AC between output and shell: all last for one minute.
Working Temperature: -10-+ 60°C
Relative Humidity: 20-90% RH
Safety Standards: Complying with CE standard
EMC Standards: Complying with CE standard
Technical Specification |
||||
Max. Output Wattage |
36-60W |
|||
Input |
Voltage |
90-260V AC |
||
Frequency |
50-60Hz |
|||
Current (Full load) |
2.0A Max. (115V AC), 1.2A Max. (230V AC) |
|||
Inrush Current |
Cold Start 40A/230V AC |
|||
Leakage Current |
<2mA (240V AC) |
|||
Output |
Voltage |
5V DC |
12V DC |
24V DC |
Voltage Accuracy |
±3% |
±2.5% |
±1.25% |
|
Max. Current |
8 |
5 |
3 |
|
Line Regulation |
±0.5% |
±0.5% |
±0.5% |
|
Load Regulation |
±1% |
±1% |
±1% |
|
Min. Load |
0% |
0% |
0% |
|
Typical Efficiency |
83% |
84% |
88% |
|
Adjustable Range of Voltage |
4.5-6.5V DC |
9-15V DC |
22-27V DC |
|
Max. Ripple & Noise |
150mV |
150mV |
150mV |
|
Hold-up Time |
20ms Min. |
|||
Switching Frequency |
60KHz |
|||
Protection |
Over Load |
105-150% of Rated Output Power Protection Type: Auto Recovery |
||
Short Circuit |
Protection Type: Auto Recovery |
|||
Electric Strength |
Input-Output |
1500V AC |
||
Input-FG |
1500V AC |
|||
Output-FG |
1500V AC |
|||
Isolation Resistance |
Input-Output, Input-FG, Output-FG: 100Mohms/500V DC |
|||
Environment |
Operating Temperature |
-10-+50°C (Refer to The Point 4 Output Load Deration Curve) |
||
Storage Temperature |
-25-+85°C |
|||
Temperature Coefficient |
±0.03%°C(0°C<t<50°C) |
|||
Humidity |
95%RH |
|||
MTBF |
>50000h@25°C(MIL-HDBK-217F) |
|||
Vibration |
10-500Hz, 2G 10Min./Cycle, 60Min. Along X, Y, Z Axes |
|||
Feature |
Dimension(L*W*H) |
|
||
Weight |
|
|||
Cooling Method |
Naturally Air-cooled |
|||
Safety & EMC |
Safety Standards |
UL60950 EN60950 |
||
EMI |
EN55011 Class B EN55022 Class B |
|||
EMS Immunity |
EN55024 EN61000-6-2 |
|||
Harmonic Current |
EN61000-3-2 |