Introduction
An input/output module is also known as a combination module,it is a device used in addressable fire alarm systems that combines the functions of both an input module and an output module. The key features and capabilities of an input/output module include:
Input Monitoring:
The input/output module can monitor the status of various input devices, such as:
Sprinkler flow switches
Tamper switches
Elevator recall inputs
HVAC system status signals
Other auxiliary sensors and detectors
It reports any changes in the status of these connected inputs to the fire alarm control panel.
Output Control:
In addition to input monitoring, the input/output module can also control and activate various output devices, such as:
Audible alarms (horns, bells, speakers)
Visual alarms (strobe lights)
Relay-controlled devices (elevators, HVAC systems, door hold-open devices)
The module can turn these outputs on and off as required by the fire alarm system.
Addressability:
Like other addressable devices, the input/output module has a unique digital address recognized by the fire alarm control panel.
This enables the control panel to precisely identify the location and status of the connected inputs and outputs.
Supervised Monitoring:
The input/output module monitors both its input and output connections for proper operation and fault conditions, such as open circuits or short circuits.
This supervisory monitoring helps ensure the reliability and integrity of the fire alarm system's input and output devices.
Integration with Other Systems:
The input/output module can be used to interface the fire alarm system with other building systems, such as HVAC controls, elevator recall, and access control systems.
This integration enables a coordinated emergency response and helps ensure the safety of building occupants.
The use of input/output modules, or combination modules, provides the benefits of both input monitoring and output control in a single addressable device. This can simplify system design, reduce installation complexity, and improve overall system integration and functionality.
Parameters
Product name | Input&Output Module | Type | Addressable |
Loop Bus wired | 2-wire Non-polarized | Monitor Current | ≤350uA |
Alarm Currrent | ≤2mA | Dimension | Φ85*40 mm |
Work voltage | DC17V~DC33V | Operating Environment | Temperature -10°C~+50°C Humidity ≤95%. |
Weight | Weight:60g(with base) | Contact Capacity | DC24V/2A,Normal Open |
Connection between Input Module
Connection Diagram of Fire Alarm System
Product range
Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector
Service
1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.
5. Welcome sample order.