Specifications
Brand Name :
XHA
Model Number :
XHA8015
Certification :
CE
Place of Origin :
China
MOQ :
1PCS
Price :
negotiable
Payment Terms :
T/T, Western Union
Supply Ability :
10000PCS/Month
Delivery Time :
3 Working days
Packaging Details :
30pcs/carton
Working Voltage :
DC9-28V
Applications :
Gas Extinghushant Control System, Fire Alarm System
Type :
Conventional Smoke Alarm With Remote LED control function
Monitor Current :
≤800uA
Alarm Current :
≤20mA
Operating Humidity Range :
10% to 95% Relative Humidity(Non-condensing)
Description

2 Wired Conventional Smoke Alarm For FM200 Gas Extinghuishant Control System

2 Wired Conventional Smoke Alarm 75dB-115dB For FM200 Gas Extinghuishant Control System

Introduction

Conventional smoke detectors are a fundamental component of gas extighuishant and fire alarm systems, serving as the primary means of detecting the presence of smoke and initiating an alarm. These devices play a vital role in early fire detection, allowing building occupants to be alerted and evacuate the premises in a timely manner.

Key characteristics and functions of conventional smoke detectors include:

Smoke Sensing Technology:
Photoelectric Smoke Detectors: These detectors use a light source and a photosensitive sensor. Smoke particles entering the detection chamber scatter the light, causing it to reach the sensor and activate the alarm.

Alarm Initiation:
When smoke particles are detected, the smoke detector sends a signal to the fire alarm control panel, which then activates the overall fire alarm system, including audible and visual notification devices.


Conventional Configuration:
Conventional Smoke Detectors: These detectors are wired in a simple, non-addressable configuration, with multiple detectors connected to a single zone on the control panel.


Power Supply:
Conventional smoke detectors are typically powered by the fire alarm control panel, drawing their electrical power from the system's supervised circuits.


Maintenance and Testing:
Regular inspection, cleaning, and functional testing of conventional smoke detectors are essential to ensure their reliable operation in the event of a fire.

Parameters

Voltage ranges

20vdc to 27vdc (Nonpolarity)

Working Current ≤40ma
Sound level

75dB-115dB (A) @3M

Material of cover Aluminum
Operating Temp -10℃ to +55℃
Operating Humidity Range

10% to 95% Relative Humidity(Non-condensing)

Application in Addressable Fire Alarm System

2 Wired Conventional Smoke Alarm 75dB-115dB For FM200 Gas Extinghuishant Control System

Product Range

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector

Service

1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.
5. Welcome sample order.

Send your message to this supplier
Send Now

2 Wired Conventional Smoke Alarm 75dB-115dB For FM200 Gas Extinghuishant Control System

Ask Latest Price
Brand Name :
XHA
Model Number :
XHA8015
Certification :
CE
Place of Origin :
China
MOQ :
1PCS
Price :
negotiable
Contact Supplier
2 Wired Conventional Smoke Alarm 75dB-115dB For FM200 Gas Extinghuishant Control System
2 Wired Conventional Smoke Alarm 75dB-115dB For FM200 Gas Extinghuishant Control System

Shenzhen Xinhe'an Technology Co., Ltd.

Verified Supplier
2 Years
guangdong, shenzhen
Since 2001
Total Annual :
4300000-7140000
Employee Number :
40~50
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement