Inline 6 Diesel NTAA855- G7 Cummins G Drive Engines For Trailer Type Generator
Product Description:
MODEL | XS-300 | |||||||
Standby Power(50Hz) | 412.5KVA | |||||||
Prime Power(50Hz) | 375KVA | |||||||
ENGINE DATA | ||||||||
Model: | NTAA855-G7 | |||||||
Air Intake System: | Turbo, Air/Air cooling | |||||||
Fuel System: | PT type fuel pump, EFC | |||||||
Cylinder Arrangement: | 6 in line | |||||||
Displacement: | 14L | |||||||
Bore and Stroke: | 140×152 mm | |||||||
Compression Ratio: | 14:1 | |||||||
Rated RPM: | 1500rpm | |||||||
Base Output Power: | 343KW | |||||||
Standby Power: | 377KW | |||||||
Governor Type: | Electronic | |||||||
Exhaust System | ||||||||
Exhaust Gas Flow: | 1150L/s | |||||||
Exhaust Temperature: | 451°C | |||||||
Max Back Pressure: | 10kPa | |||||||
Air Intake System | ||||||||
Max Intake Restriction: | 6.22kPa | |||||||
Consumption: | 510L/s | |||||||
Fuel System | ||||||||
110% Standby Load Consumption: | 94L/h | |||||||
100%(Prime Power) Load Consumption: | 85.4L/h | |||||||
75%(Prime Power) Load Consumption: | 64.7L/h | |||||||
50%(Prime Power) Load Consumption: | 44.6L/h | |||||||
25%(Prime Power) Load Consumption: | 24.6L/h | |||||||
Oil System | ||||||||
Oil Pan Capacity (Max/Min): | 36/28.4 L | |||||||
Max. Oil Temp. Permitted in Oil Pan: | 121°C | |||||||
Cooling System | ||||||||
Total Coolant Capacity: | 63.9L | |||||||
Thermostat: | 82-94°C | |||||||
Max Water Temperature: | 96°C | |||||||
ALTERNATOR DATA | ||||||||
Model: | Stamford HCI 444FS | |||||||
Prime Power: | 304KW | |||||||
Frequency and Speed: | 50HZ / 1500 RPM | |||||||
Connecting Type: | 3 Phase and 4 Wires, “Y” type connecting | |||||||
Power Factor: | 0.8 | |||||||
Altitude: | ≤1000m | |||||||
Exciter Type: | Brushless, self-exciting, with AVR | |||||||
Insulation Class, Temperature Rise: | H/H | |||||||
GENERATING SET DATA | ||||||||
Voltage Regulation: | ≥±5% | |||||||
Voltage Regulation, Stead State: | ≤±1% | |||||||
Sudden VoltS Warp(Sudden Reduce): | ≤+25% | |||||||
Sudden Voltage Warp(Sudden Increase): | ≤-20% | |||||||
Frequency Regulation, Stead State: | ≤5% | |||||||
Frequency Waving: | ≤0.5% | |||||||
Frequency Warp(Sudden Reduce): | ≤+12% | |||||||
Frequency Warp(Sudden Increase): | ≤-10% | |||||||
Frequency Recovery Time: | ≤5S | |||||||
Open Type Size: | 3250(mm)*1100(mm)*1800(mm) | |||||||
Open Type Weight: | 3100 Kg | |||||||
Control Panel: | Harsen GU320B automatic control panel |
Test before shippment
- Each Generator Set shall be put into commission more than 4 hours totally, tested on idle load, fully load and 10% overload.
- Noise level shall be tested.
- All of the meters on the control panel shall be tested.
- The appearance of the Set and the label, nameplate shall be tested. "
-Voltage available: 50Hz: 380-400-415V/ 220-230-240V; 60Hz: 220-380-416-440-480V/ 110-208-220-
240V. Any special voltage is also available as cilent's request.
Our Warehouse:
Our Services
1) we focus in diesel engine and engine parts for over 9 years
2) strong in resources integration
3) with freedom deep service
4) cheapest shipping
Packing&Warranty
- Packing: Wooden Case, Plywood or Metal Case.
- Delivery Time: Less than 25 working days after receiving prepayment.
- Warranty: One year or 1, 000 hours from the date of shippment
(15 Months or 1, 200 hours for Alternator Part).
Payment:
T/T, 30% deposit, 70% will be payed before delivery
T/T, 30% deposit , 70% L/C at sight
100% L/C at sight
We can also provide ORIGINAL CUMMINS engines used for Industry, Construction,Truck,Coach,Bus, Marine, Generator Set and Water/Fire pumps.
More details, please contact us by email or call.
Welcome to contact us. Thanks !