Specifications
Brand Name :
XZH TEST
Model Number :
XHHV535-4Z
Certification :
CE
Place of Origin :
Xi'an, Shaanxi, China
MOQ :
1 unit
Payment Terms :
T/T
Supply Ability :
1000 units/month
Delivery Time :
5-8 work days
Packaging Details :
Wooden case
Impulse voltage :
Default 0~28kV ( 0~32kV customizable)
High voltage partial pressure :
2.5
Built-in capacitor :
4μF
Discharge power :
0~1568 J ( 0~2048 J customizable)
Output voltage polarity :
Negative polarity
Impact power :
400W
Over temperature protection :
85℃
Working power supply :
AC 220V±10% / 50Hz±2Hz
Ambient temperature :
-20~+50℃
Description

The high-voltage pulse generator XHHV535-4Z fully complies with DL/T846-2016 "General Technical Conditions for High Voltage Test Equipment" and DL/T474-2017 "Guidelines for the Implementation of Field Insulation Tests". It is mainly used for impact discharge during fault testing of cables with voltage levels of 35kV and below; it can also be used for DC withstand voltage tests of other electrical equipment.

This device integrates DC high-voltage source, energy storage capacitor, and discharge ball gap into one. This equipment completely replaces the traditional test transformer weighing hundreds of kilograms, operation box and pulse energy storage capacitor (generally a set of 5kVA transformer weighs more than 60 kg, and the control box more than 30 kilograms, and more than 20 kilograms of pulse energy storage capacitors).

The power supply adopts high-precision, high-stability special high-voltage electronic components and high-frequency high-voltage technology, which makes the whole machine simple in structure and ultra-light in weight. The pulse generator adopts humanized design and operation mode, which is safe and reliable. It really achieves the effect of not being damaged by impact, and it can also work normally when the high voltage is short-circuited to the ground. It is currently the lightest and most user-friendly portable DC impact high-voltage equipment. It is an ideal product for power cable fault detection.

Automatic Discharge Adjustable Pulse Rate 32kV Underground Cable Fault Location 1500J High Voltage Surge Generator


Technical parameters

Impact high voltage 0~28kV(0-32kV customizable)
High voltage partial pressure 2.5 level
Built-in capacitor 4μF
Discharge power 1568J(2048J@32kV)
Impact power 400W
Over temperature protection 85℃
Volume(mm) 420L×325W×480H
Weight not more than 40kg
Power supply AC220V±15%, 50Hz±2Hz(60Hz can be customized)
Ambient temperature -20~+50℃

Panel introduction

Automatic Discharge Adjustable Pulse Rate 32kV Underground Cable Fault Location 1500J High Voltage Surge Generator

1.High voltage output (DC): When DC withstand voltage, connect the high voltage output line.


2.High voltage output (EMP): When impact discharge, connect the high voltage output line.


3.Safety ground: the ground of the instrument casing, to prevent the instrument casing from being electrified or personnel from getting an electric shock.


4.Time setting: set the discharge time interval.


5.Voltmeter: High voltage output voltage indication, used to display voltage value in real time.


6.Power outlet: instrument working power, AC 220V±10%/50Hz±1Hz.


7.Fuse socket: where the fuse of the AC 220V power supply system is installed.


8.Power switch: "Stage Ⅰ" means to turn on the AC 220V power supply to supply power to the system;
"Gear 0" means turn off the AC 220V power supply to power the system.


9.Over-current protection switch: When pressed, it means that the over-current protection function has started; when it is popped up, it means that the instrument has triggered the over-current protection.


10.Start button/zero indicator light:
When the zero indicator light is on (yellow), it means that it is in the zero state, press the start button to start the high voltage output;
When the zero position indicator light is off, it means that it is not in the zero position state. After turning the voltage adjustment knob counterclockwise to the zero position, the zero position indicator light is on, and then press the start button to start the high voltage output.


11.Stop button/high-voltage indicator light: When the test is completed or abnormality occurs, press this button to cut off the high-voltage output, the high-voltage indicator light is on, indicating that the high-voltage output has been started; the high-voltage indicator light is off, indicating that the high-voltage output has stopped.


12.Voltage adjustment knob: used to adjust the voltage; adjust the output high voltage clockwise to increase from small to large, and adjust the output high voltage counterclockwise to decrease from large to small.


13.Discharge button: When the high voltage is stopped, press this button to manually discharge the internal storage power.


14.Ammeter: Indicates the magnitude of the low-voltage measurement current.


15.Sampling place: The negative terminal of the pulse energy storage capacitor has a high voltage and must be reliably grounded. It is used for sampling when the waveform is sampled in the high-voltage flashover state of the cable fault tester. (Sampling without high-voltage flashover still requires reliable grounding).


16. High-voltage ground: also known as high-voltage tail, the internal devices of the instrument are grounded.

In the latest design, grounding posts 3, 15, and 16 are combined into one.


Packing list

Automatic Discharge Adjustable Pulse Rate 32kV Underground Cable Fault Location 1500J High Voltage Surge Generator


Onsite testing

Automatic Discharge Adjustable Pulse Rate 32kV Underground Cable Fault Location 1500J High Voltage Surge GeneratorAutomatic Discharge Adjustable Pulse Rate 32kV Underground Cable Fault Location 1500J High Voltage Surge GeneratorAutomatic Discharge Adjustable Pulse Rate 32kV Underground Cable Fault Location 1500J High Voltage Surge Generator


Company profile

XZH TEST is a professional cable fault detection equipment manufacturer. We are a young team. Our development philosophy is humanized management, intelligent cloud-based products, and internationalized operations. Our development mission is to make electrical equipment free from undetectable failures.

Since its inception in 2013, our company has grown to become one of the largest manufacturer of underground cable fault detection equipment in China. An ISO 9001 and CE certified company, we produces a broad range of testing equipment.

What we can do

We have the ability to innovate new products and technologies.

We can provide complete system solutions for your project.

We provide online and offline practical and theoretical training.

We provide instrument repair and calibration.

Automatic Discharge Adjustable Pulse Rate 32kV Underground Cable Fault Location 1500J High Voltage Surge Generator

Automatic Discharge Adjustable Pulse Rate 32kV Underground Cable Fault Location 1500J High Voltage Surge Generator

Automatic Discharge Adjustable Pulse Rate 32kV Underground Cable Fault Location 1500J High Voltage Surge Generator

Automatic Discharge Adjustable Pulse Rate 32kV Underground Cable Fault Location 1500J High Voltage Surge Generator

Automatic Discharge Adjustable Pulse Rate 32kV Underground Cable Fault Location 1500J High Voltage Surge Generator

Automatic Discharge Adjustable Pulse Rate 32kV Underground Cable Fault Location 1500J High Voltage Surge Generator


FAQ

1. Are you a trading company or a manufacturer?

We are a professional manufacturer with more than 10 years of experience. We can strictly control the quality of parts and finished products.

2. What is the delivery time and inventory?

If our best-selling products are in stock, it will be 5-8 working days for shipment. But for mass production and customized production, the time will take 2-4 weeks.

3. What are your payment terms?

Payment ≤ USD 2000, 100% T/T prepayment. Orders over USD 2000 can be negotiated.

4. How long is your product warranty?

We provide 1 year warranty for the equipment.

5. How do you ensure quality?

The product links include R&D, manufacturing, commissioning and technical support, following strict and scientific management principles. Therefore, we can support strong production and R&D capabilities, and can produce high-quality products at competitive prices to meet customers' high requirements.

6. What support can I get?

We will provide training support, marketing support, technical support and supply chain support. You can contact us for more information.

7. Where is your factory? Can I visit your factory?

We are located in Xi'an, Shaanxi, China. We are close to Xi'an Xianyang International Airport, which is about 2 and half hours by plane from Shanghai and Guangzhou. All customers from all over the world are welcome to visit us.

8. How to become your dealer?

Every company interested in power system instruments can contact us without hesitation, including website letters, emails, telephones, etc. We will contact you quickly according to your company information and cooperation intentions.

Send your message to this supplier
Send Now

Automatic Discharge Adjustable Pulse Rate 32kV Underground Cable Fault Location 1500J High Voltage Surge Generator

Ask Latest Price
Brand Name :
XZH TEST
Model Number :
XHHV535-4Z
Certification :
CE
Place of Origin :
Xi'an, Shaanxi, China
MOQ :
1 unit
Payment Terms :
T/T
Contact Supplier
Automatic Discharge Adjustable Pulse Rate 32kV Underground Cable Fault Location 1500J High Voltage Surge Generator
Automatic Discharge Adjustable Pulse Rate 32kV Underground Cable Fault Location 1500J High Voltage Surge Generator
Automatic Discharge Adjustable Pulse Rate 32kV Underground Cable Fault Location 1500J High Voltage Surge Generator
Automatic Discharge Adjustable Pulse Rate 32kV Underground Cable Fault Location 1500J High Voltage Surge Generator
Automatic Discharge Adjustable Pulse Rate 32kV Underground Cable Fault Location 1500J High Voltage Surge Generator

Xi'an Xu&Hui Electromechanical Technology Co., Ltd.

Verified Supplier
1 Years
Since 2013
Business Type :
Manufacturer
Total Annual :
1000000-5000000
Employee Number :
50~100
Certification Level :
Verified Supplier