Parameter | |||||||
MODEL(HC) | 1kw | 1.5kw | 2kw | 3kw | 4kw | 5KW | 6KW |
Continuous Output Power (W) | 1000W | 1500W | 2000W | 3000W | 4000W | 5000W | 6000W |
Rated input voltage | 12VDC/24VDC/48VDC | 12VDC/24VDC/48VDC | 24VDC/48VDC | ||||
Mains mode specifications: | |||||||
Input voltage waveform | Sine wave (mains or generator) | ||||||
Rated input voltage | 100V/ 110V/ 120V/220V/230V/240Vac | ||||||
Low voltage shutdown point | 92/ 184Vac±4% | ||||||
Low pressure recovery point | 97/ 194Vac ±4% | ||||||
High voltage shutdown point | 127/253Vac±4% | ||||||
High pressure recovery point | 121/243Vac±4% | ||||||
Maximum AC input voltage | 135/270V rms |
Rated input frequency | 50Hz/ 60Hz (automatic detection) | |||||||
Low voltage recovery point frequency | 40.5+0.3Hz ; | |||||||
Low voltage cut-off point frequency | 40+0.3Hz; | |||||||
High voltage recovery point frequency | 69.5+0.3Hz; | |||||||
High voltage cut-off point frequency | 70+0.3Hz ; | |||||||
Output voltage waveform | Consistent with the input voltage waveform | |||||||
Overload protection | Circuit breaker start | |||||||
Short circuit protection | Circuit breaker start | |||||||
Power Efficiency | >95% | |||||||
Conversion current | 30A | |||||||
Conversion time (Ac to Dc) | 10ms | |||||||
Bypass switching current | Yes | |||||||
Bypass maximum load current | 30A | |||||||
Output voltage waveform | Sine wave | |||||||
Power factor | 0~1.0 | |||||||
Rated output voltage (V) | 120/230Vac | |||||||
Rated output frequency (Hz) | 60/50Hz ± 0.3Hz | |||||||
Automatic tracking main frequency (Hz) | Yes (from the first connection) | |||||||
Output voltage range | ±2% rms | |||||||
efficient | >80% | |||||||
Overload protection (SMPS load) | (110%<load<125%) ±10%: disconnect the output voltage after 15 minutes (125%<load <150%) ±10%: disconnect the output voltage after 10 seconds Load >150% ±10%: Disconnect the output voltage after 20 seconds | |||||||
Peak capacity( 10s) | 3000VA | 4500VA | 6000VA | 9000VA | 1200VA | 15000VA | 18000VA | |
start the motor | 1HP | 1.5HP | 2HP | 3HP | 4HP | 5HP | 6HP | |
Short circuit protection | Current limit (power off after 10s) | |||||||
Circuit breaker size | 15A | 20A | 30A | 40A | ||||
Rated DC input voltage | 12V / 24V/48V | |||||||
Minimum DC terminal voltage | 10V/20V/40V | |||||||
Undervoltage warning | 10.5Vdc ± 0.3Vdc (12V power supply) | |||||||
DC input voltage is too low, automatic power off | 10.0Vdc ± 0.3Vdc(12V power supply) | |||||||
Input overvoltagewarning and power failure | 16Vdc ± 0.3Vdc (12Vpower supply) | |||||||
Input overvoltage recovery | 15.5Vdc ± 0.3Vdc(12V power supply) | |||||||
Power saving | load ≦2W | |||||||
Inverter dimensions | 360*185* 180mm | 420*185* 180mm | 597* 195* 190mm |
(Length*width*height) | |||||||
Packing size (length*width*height) | 520*315*305 | 580*315*305mm | 760*325*310mm | ||||
Inverter weight | 13.5KG | 14KG | 17KG | 21KG | 27KG | 29.5KG | 30.5KG |
Packing operating weight | 15.5KG | 15.5KG | 19KG | 23.5KG | 29.5KG | 31.5KG | 32.5KG |
Standard warranty | 2 year |
If the product model specification changes without notice