PRODUCT DESCRIPTION:
HT series is our company's maximum power point intelligent tracking (MPPT) solar charge controller. It has high efficiencyRate conversion rate, high stability, automatic system identification, PV wide voltage range input,Can charge a variety of batteries, professional upper computer monitoring software and other advantages
PRODUCT FEATURES:
1. Applicable to 12V/24V/36/48V system, automatic identification of system voltage, parallel design, and expansion of system capacity.
2. Four-stage charging improves the charging efficiency and improves the performance of the battery pack.
3. MPPT tracking efficiency can reach 99.5%, charging efficiency 97.5%.
4. Effectively extend the battery life, LCD screen and LED indicator display, can view any parameters and operating conditions in real time
5. Support PC software monitoring, support WI FI4G module expansion to realize app cloud monitoring (optional)
6. It is suitable for charging various lead-acid batteries, gel batteries and the latest technology lithium batteries.
7. Perfect protection function makes the controller not easy to be damaged
8. Double fan heat dissipation, economical structure design, lower cost and benefit more consumers
9. Simple installation and connection method, saving installation time and steps
10. The computer monitoring software can set various parameters, monitor the real-time operation of the system, and store data
11. Optional port RS485/232, Ethernet effectively improves power generation efficiency, which is more than 30% higher than traditional PWM solar chargers
Model: MPPT-40/50/60 Series |
50A |
60A | |
Charging Mode | MPPTAutomatic maximum power point tracking | ||
Charging Method | Three stages: constant current (MPPT), balanced charge, floating charge | ||
System Type | 96V | Automatic identification / manual setting | |
System voltage range | 96V System | DC72V-DC120V | |
Soft start time | 96V | W10s | |
Dynamic response recovery time | 96V | W500us | |
Static power | 96V | W2W | |
Efficeny |
96V |
>9 6. 5% | |
PV module utilization | 96V | W99. 97% | |
Input Features | |||
MPPT working Voltage | 96V | DC130V-DC180V |
Input low voltage protection point | 96V | DC120V | |
low voltage input recovery point | 96V | DC130V | |
Max PV input Voltage | 96V | DC225V | |
Over voltage protection | 96V | DC230V | |
Over voltage input recovery | 96V | DC225V | |
MAX solar input power | 96V System | 5600W | 6800W |
Output Features | 96V system without DC output | ||
Battery Type(The default isislead-acid )maintenance-f ree battery) |
96V | Lead-acid maintenance-free batteries, gel batteries, liquid batteries, lithium batteries (You can also customize to charge other types of batteries) | |
Floating voltage (Lead-acid batteries) | 96V | 110. 4V | |
Charging voltage (Lead-acid batteries) (can be set by user) |
96V |
116V | |
Rated Current | 96V | 50A | 60A |
Current limit protection | 96V | 52A | 62A |
Temperature Coefficient | 96V | ±0. 02%/℃ | |
Automatic temperature | 96V | 14. 2V-( maximum temperature-25℃) *0.3 | |
Output voltage regulation | 96V ^±1.5% | ||
LCD displaying LCD display instructions for details | |||
LED displaying Charging indication' DC output switch status indication | |||
PC Upper computer(Communication PORT) Rs485(optional) | |||
Protections | |||
Input low voltage | See input characteristics | ||
Input high voltage | See input characteristics | ||
Input polarity reverse | With reverse polarity protection | ||
Output polarity reverse | With reverse polarity protection | ||
Short circuit protection | Enter the protection state after 5 trial startups, and resume from startup | ||
Temperature protection | 85 degrees | ||
Temperature rise | Reduce power output above 80"C | ||
Other Data | |||
Noise | W50dB | ||
| Forced air cooling, the fan speed is adjusted by temperature, when the internal temperature is low, the fan runs slowly or stops; when the controller stops working, the fan stops running; | ||
element | Imported materials, in line with EU standards. The rated temperature of the electrolytic cell for all temperature selections is not less than 105℃ | ||
odor | Does not produce peculiar smell and harmful smell | ||
Environment | Meets 2002/95/ EC; no cadmium, hydride and fluoride |
Machine size | Length*width*height( mm) | 245*190*95 |
Package dimensions | Length*width*height( mm) | 285*270* 140 |
net weight | Kilogram(KG) | 3.5 |
Gross weight | Kilogram(KG) | 4 |
If the product model specification changes without notice