Air Compressor Water Separator
The WS gas-water separator is designed to effectively remove a large amount of liquid contaminants in the compressed air.
Feature & Advantage
· Protect the coalescing filter from a large amount of liquid pollution
· Helps to provide air quality, in line with ISO8573-1:2010, the international standard for compressed air quality
· Suitable for all compressed air applications, suitable for all compressor types
· Low operating cost, low pressure loss, low life cycle cost
· All WS series gas-water separators are covered by a 15-year shell warranty
The Water Separator Filter is compact and beautiful in appearance, durable, and the pressure loss is negligible. And there is an imported Automatic Drain Valve inside, no need to replace components. It is not only an ideal component for screw compressors, but also an indispensable water removal device for general air compressor post-processing.
Removal of water in compressed air is the primary task of compressed air purification. The water entrained in compressed air will corrode pipelines, valves, instruments and equipment, resulting in increased production costs.
Scope of Application
1. Separation and recovery of compressed air condensate
2. Condensate separation in steam line
3. Air Separation of inlet/outlet of gas-liquid mixing part
4. Separate and discharge condensate in the vacuum system
5. Condensate separation after water cooling tower
6. Geothermal steam separator
7. Various other gas-liquid separation applications
Technical Specification
Model | Pipe Size | Flow rates | Dimension(mm) | ||||||
L/S | m³/min | cfm | W(Weight) | H(High) | A | B | C (clearance for housing) | ||
TWS009 | RC1/4" | 15.0 | 0.9 | 31.8 | 81 | 197 | 24.6 | 173.9 | 50.5 |
TWS010 | RC3/8" | 25.1 | 1.5 | 53.0 | 81 | 197 | 24.6 | 173.9 | 50.5 |
TWS011 | RC1/2" | 46.8 | 2.8 | 98.8 | 108 | 249 | 30.1 | 220.6 | 53.3 |
TWS012 | RC3/4" | 66.8 | 4.0 | 141.2 | 108 | 249 | 30.1 | 220.6 | 53.3 |
TWS014 | RC3/4" | 86.8 | 5.2 | 183.6 | 108 | 289 | 30.1 | 260.6 | 53.3 |
TWS016 | RC1" | 130.3 | 7.8 | 275.3 | 133 | 332 | 40.7 | 291 | 59.6 |
TWS018 | RC1-1/2" | 175.4 | 10.5 | 370.7 | 133 | 332 | 40.7 | 359.8 | 59.6 |
TWS020 | RC2" | 300.0 | 18.0 | 636.0 | 170 | 617 | 52.92 | 662.97 | 59.6 |
Technical requirements | Maximum operating pressure: 10barg Operating temperature: from 1.5℃ to 80°C |
Pressure | Barg | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Psig | 15 | 29 | 44 | 59 | 73 | 87 | 100 | 116 | 131 | 145 | 160 | 174 | 189 | 203 | 219 | 232 | |
Correction factor | 0.38 | 0.53 | 0.65 | 0.76 | 0.85 | 0.93 | 1.00 | 1.07 | 1.13 | 1.19 | 1.23 | 1.31 | 1.36 | 1.41 | 1.46 | 1.51 |