How Often to Drain Gas Water Separator?
Since the work of the gas-water separator is a continuous process, if the water in the separator is artificially discharged, the labor cost will increase, and the uncertain factors will lead to the inability to drain water in time and increase the maintenance cost.
Therefore, it is very necessary to have an Automatic Drain.
The automatic drainer can drain water in time according to the condensate inside the gas-water separator to ensure sufficient gas-liquid separation area.
Feature & Benefit & Advantage
> High liquid removal efficiencies at all flow conditions
> Protects coalescing filters from bulk liquid contamination
> Helps provide air quality in accordance with ISO 8573-1:2001 the international standard for compressed air quality
> Suitable for all compressed air applications, Suitable for all compressor types, including variable flow
> Low pressure losses for low operational costs, Low lifetime costs
> All FWS water separators are covered by a 15 year housing guarantee
> Reduce moisture rusting of pipelines and damage to valves, cylinders, electronic components and other equipment
> Protect the filter in front of the dryer and suction dryer
> Efficiently remove liquid in compressed air
> Improve air quality
Technical Specification
Model | Pipe size | Flow rates | Dimension (mm) | |||||||
L/S | m³/min | scfm | W(Width) | D(Depth) | H(Height) | A | B | C (clearance for housing) | ||
FWS010 | RC1/2" | 40.0 | 2.4 | 84.5 | 96 | 79 | 233 | 29 | 198 | 118 |
FWS020 | RC3/4" | 60.0 | 3.6 | 127.1 | 96 | 79 | 233 | 29 | 198 | 118 |
FWS050 | RC1" | 75.0 | 4.5 | 158.9 | 96 | 79 | 268 | 29 | 233 | 153 |
FWS060 | RC1" | 125.0 | 7.5 | 264.8 | 138 | 111 | 339 | 37 | 296 | 208 |
FWS070 | RC1-1/2" | 166.7 | 10.0 | 353.1 | 138 | 111 | 339 | 37 | 296 | 208 |
FWS100 | RC2" | 300.1 | 18.0 | 635.6 | 174 | 142 | 669 | 58 | 607 | 469 |
FWS110 | RC2-1/2" | 416.8 | 25.0 | 882.8 | 174 | 142 | 669 | 58 | 607 | 469 |
FWS131 | RC2-1/2" | 700.0 | 42.0 | 1483.1 | 220 | 184 | 726 | 74 | 649 | 514 |
FWS140 | RC3" | 833.5 | 50.0 | 1765.6 | 220 | 184 | 726 | 74 | 649 | 514 |
FWS140F | DN80/DN100 | 833.5 | 50.0 | 1765.6 | 300 | 184 | 746/761 | 74 | 649 | 514 |
FWS150 | RC4" | 1000.2 | 60.0 | 2118.7 | 220 | 184 | 726 | 74 | 649 | 514 |
FWS150F | DN100/DN125 | 1000.2 | 60.0 | 2118.7 | 300 | 184 | 761/776 | 74 | 649 | 514 |
FWS170 | RC4" | 1166.7 | 70.0 | 2464.0 | 220 | 184 | 983 | 74 | 906 | 764 |
FWS170F | DN100/DN125 | 1166.7 | 70.0 | 2464.0 | 300 | 184 | 1018/1033 | 74 | 906 | 764 |
Technical requirements | Maximum operating pressure: 10 barg Operating temperature:1.5~ 80°C |
Pressure | Barg | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Psig | 15 | 29 | 44 | 59 | 73 | 87 | 100 | 116 | 131 | 145 | 160 | 174 | 189 | 203 | 219 | 232 | |
Correction factor | 0.38 | 0.53 | 0.65 | 0.76 | 0.85 | 0.93 | 1.00 | 1.07 | 1.13 | 1.19 | 1.23 | 1.31 | 1.36 | 1.41 | 1.46 | 1.51 |