Specifications
Model No. :
YD030
Origin :
China
Element Serve Life :
6000~8000 Hours
Trademark :
Yuka
HS Code :
8421399090
Clapboard :
Without Clapboard
Filter Number :
1
Medium Material :
Fiberglass
Type :
Cartridge Filter
Material :
Aluminum Alloy
Housing Serve Lige :
15 Years
Filtration Performance :
From 5 μm To 0.01μm
Maxi. Operate Pressure :
1.0mpa
Operate Temperature :
1.5~80ºc
Resistance Corrosion :
Inside And Outside
Parts :
Dp Indicator, Auto Drain, Sight Glass
Transport Package :
Brown Inner Box & Cardboard
Efficiency :
F9
Filtration Grade :
Medium Filter
Connection :
Rc1/2"
Flow Rate :
1.8m³/Min
Diversion Fin Design On Element Top Cap :
Less Pressure Loss
OEM & ODM Service :
Yes
Pressure Loss :
About 0.25 Bar
Bleed Valve :
Available
Specification :
Dimension:89x 79x 280mm
Place of Origin :
China
Brand Name :
Yuka
Price :
Negotiable
Packaging Details :
Box Package
Delivery Time :
3-7working days
Payment Terms :
L/C,T/T
MOQ :
50pcs
Supply Ability :
300,000pcs/month
Description
Product Description

The compressed air quality reaches ISO8573.1 quality level 1. In this way, the clean and dry compressed air can enter the nitrogen production part of the subsequent stage to produce nitrogen with a purity of ≥98% through pressure swing adsorption. Therefore, the right Compressed Air Filter matching program can be selected to obtain high-quality nitrogen.

Let’s take a look at the different types of air filters and the questions that will help you choose the correct filter.

①Assess the requirements of your application. Different industry require different solution. ③Any specific micron of filtration performance you required?
②What type of filtration is needed? Coalecent filter material removes solid and liquied contaminants from gas streams. Particulate filter media removes solid from gas streams. Absorber media removes hydrocarbon vapors from gas streams.
④What are the working conditions of your application? Mainly criteria of consider : Flow, working pressure, temperature,pressure loss,material of structure (stainless steel, aluminum alloy, mild steel, carbon steel)
⑤Filter flow rate from how much SCFM? Pressure drop should be less than **bar? For saving the cost and protect environment.

PRODUCT OVERVIEW

Commodity Compressed air filter
Model YD030
Flow rate 1.8m³/min
Element grade 5μm/1μm /0.01μm/0.001mg/m³
Working pressure 143 psi g
Working temperature 1.5~80
Material Aluminum Alloy
Color of housing Red
Trade term EXW & FOB SHENZHEN
Package Internal Box & External Carton
Warranty 15 years for filter housing, 4000-6000 hours under rated working conditions for Filter Element

Compressed Air Filter For Nitrogen Generator

Filter Element Grade

Filtration Grade Compressed Air Filter For Nitrogen Generator Compressed Air Filter For Nitrogen Generator Compressed Air Filter For Nitrogen Generator Compressed Air Filter For Nitrogen Generator Compressed Air Filter For Nitrogen Generator Compressed Air Filter For Nitrogen Generator Compressed Air Filter For Nitrogen Generator
PF AO AA AX ACS AR AAR
Particle removal (ISO12500-3) 5μm 1μm 0.01μm 0.01μm - 1μm 0.01μm
Outlet oil aerosol concentration (ISO12500-1) 5mg/m³ 0.6mg/m³ <0.01mg/m³ <0.001mg/m³ <0.004mg/m³ - -
Filtration performance of Particle (ISO12500-3) - 99.999+% 99.999+% 99.999+% 99.999+% 99.999+% 99.999+%
Filtration performance of (ISO12500-1) 50% 80+% 99.9+% 99.99+% - - -
Element spanlife 6000 hours 6000 hours 6000 hours 6000 hours 2000-3000 hours 4000-6000 hours 4000-6000 hours
Precede with Before Refrigerated Air Dryer after air dryer after AO after AA before AX after desiccant dryer after AR
Technical Specification
The flow rate below is the treatment capacity of compressed air under rated working pressure 7 barg (100psi g).
For application in other working pressure, please refer to the correction factors.

Model Pipe size Flow rates Dimension (mm)
L/S /min scfm W(Width) D (Depth) H (Height) A B C(clearance for housing)
YD017 RC1/2" 16.7 1.0 35.3 89 79 246 40 186 118
YD025 RC3/4" 25.0 1.5 53.0 89 79 246 40 186 118
YD030 RC1/2" 30.0 1.8 63.6 89 79 280 40 220 158
YD035 RC3/4" 33.3 2.0 70.6 89 79 280 40 220 158
YD058 RC3/4" 46.7 2.8 98.9 120 110 377 55 276 195
YD068 RC1" 60.0 3.6 127.1 120 110 377 55 276 195
YD080 RC1" 80.0 4.8 169.5 120 110 477 55 377 290
YD145 RC1-1/2" 120.0 7.2 254.2 120 110 477 55 377 290
YD220 RC2" 200.0 12.0 423.7 162 151 676 64 566 480
YD260 RC2-1/2" 233.3 14.0 494.4 162 151 676 64 566 480
YD330 RC2" 267.2 16.0 564.8 162 151 984 64 875 780
YD360 RC2-1/2" 317.3 19.0 670.7 162 151 984 64 875 780
YD405 RC2-1/2" 367.4 22.0 776.6 200 189 757 78 634 560
YD430 RC3" 467.6 28.0 988.4 200 189 757 78 634 560
YD620 RC3" 620.0 37.2 1313.6 200 189 1012 78 889 780
Technical requirements Maximum operating pressure: 10 barg Maximum operating temperature: 80°C Minimum operating temperature:1.5°C

Pressure Barg 1 2 3 5 6 7 8 9 10 11 12 13 14 15 16
Psig 15 29 44 73 87 100 116 131 145 160 174 189 203 219 232
Correction factor 0.38 0.53 0.65 0.85 0.93 1.00 1.07 1.13 1.19 1.23 1.31 1.36 1.41 1.46 1.51


Compressed Air Filter Parts in Detail

1.1 YD017-YD035

Compressed Air Filter For Nitrogen Generator

1.2 YD058-YD145
Compressed Air Filter For Nitrogen Generator

1.3 YD220-YD620

Compressed Air Filter For Nitrogen Generator

Success Cases

Compressed Air Filter For Nitrogen Generator

Send your message to this supplier
Send Now

Compressed Air Filter For Nitrogen Generator

Ask Latest Price
Watch Video
Model No. :
YD030
Origin :
China
Element Serve Life :
6000~8000 Hours
Trademark :
Yuka
HS Code :
8421399090
Clapboard :
Without Clapboard
Contact Supplier
video
Compressed Air Filter For Nitrogen Generator

Hongrijia Depurate Facility Science & Technology Co., Ltd.

Verified Supplier
1 Years
shenzhen
Since 1998
Business Type :
Manufacturer
Total Annual :
10000000-50000000
Employee Number :
100~300
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement