Product Introduction
1.The gas-water separator has no built-in Filter Element, and uses a rotary vane device to separate by recoil power.
It is generally installed in front of the refrigerated/Adsorption Dryer to pre-separate the air and water to make the dryer have a better drying effect.
2. Installed at the front end of the precision filter to protect the filter, protect the filter material from the influence of humid air, and provide filtration accuracy and effect.
3. There is no built-in filter element in the gas-water separator, so the pressure difference can be ignored.
Feature & Benefit & Advantage
> High liquid removal efficiencies at all flow conditions
> Protects coalescing filters from bulk liquid contamination
> Helps provide air quality in accordance with ISO 8573-1:2001 the international standard for compressed air quality
> Suitable for all compressed air applications, Suitable for all compressor types, including variable flow
> Low pressure losses for low operational costs, Low lifetime costs
> All FWS water separators are covered by a 15 year housing guarantee
> Reduce moisture rusting of pipelines and damage to valves, cylinders, electronic components and other equipment
> Protect the filter in front of the dryer and suction dryer
> Efficiently remove liquid in compressed air
> Improve air quality
Technical Specification
Model | Pipe size | Flow rates | Dimension (mm) | |||||||
L/S | m³/min | scfm | W(Width) | D(Depth) | H(Height) | A | B | C (clearance for housing) | ||
FWS010 | RC1/2" | 40.0 | 2.4 | 84.5 | 96 | 79 | 233 | 29 | 198 | 118 |
FWS020 | RC3/4" | 60.0 | 3.6 | 127.1 | 96 | 79 | 233 | 29 | 198 | 118 |
FWS050 | RC1" | 75.0 | 4.5 | 158.9 | 96 | 79 | 268 | 29 | 233 | 153 |
FWS060 | RC1" | 125.0 | 7.5 | 264.8 | 138 | 111 | 339 | 37 | 296 | 208 |
FWS070 | RC1-1/2" | 166.7 | 10.0 | 353.1 | 138 | 111 | 339 | 37 | 296 | 208 |
FWS100 | RC2" | 300.1 | 18.0 | 635.6 | 174 | 142 | 669 | 58 | 607 | 469 |
FWS110 | RC2-1/2" | 416.8 | 25.0 | 882.8 | 174 | 142 | 669 | 58 | 607 | 469 |
FWS131 | RC2-1/2" | 700.0 | 42.0 | 1483.1 | 220 | 184 | 726 | 74 | 649 | 514 |
FWS140 | RC3" | 833.5 | 50.0 | 1765.6 | 220 | 184 | 726 | 74 | 649 | 514 |
FWS140F | DN80/DN100 | 833.5 | 50.0 | 1765.6 | 300 | 184 | 746/761 | 74 | 649 | 514 |
FWS150 | RC4" | 1000.2 | 60.0 | 2118.7 | 220 | 184 | 726 | 74 | 649 | 514 |
FWS150F | DN100/DN125 | 1000.2 | 60.0 | 2118.7 | 300 | 184 | 761/776 | 74 | 649 | 514 |
FWS170 | RC4" | 1166.7 | 70.0 | 2464.0 | 220 | 184 | 983 | 74 | 906 | 764 |
FWS170F | DN100/DN125 | 1166.7 | 70.0 | 2464.0 | 300 | 184 | 1018/1033 | 74 | 906 | 764 |
Technical requirements | Maximum operating pressure: 10 barg Operating temperature:1.5~ 80°C |
Pressure | Barg | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Psig | 15 | 29 | 44 | 59 | 73 | 87 | 100 | 116 | 131 | 145 | 160 | 174 | 189 | 203 | 219 | 232 | |
Correction factor | 0.38 | 0.53 | 0.65 | 0.76 | 0.85 | 0.93 | 1.00 | 1.07 | 1.13 | 1.19 | 1.23 | 1.31 | 1.36 | 1.41 | 1.46 | 1.51 |