What is compressed air filtration?
Compressed air filtration is one of the most usual and most important forms of filtration in the industrial market. Coalescer, particulate, and carbon absorption filters are the three most usual types of compressed Air Filters.
YUKA compressed air filters are placed at strategic locations throughout the compressed air system to protect equipment such as refrigeration air dryers, cylinders, valves, and lasers. In order to meet these requirements, our filters are offered in a micron range of 0.01 - 5 micron.
Our coalescing filters use a specially formulated borosilicate glass media to achieve coalescing results of down to 0 .003 ppm oil carry over.
Tenical Specification
The flow rate below is the treatment capacity of compressed air under rated working pressure 7 barg (100psi g). For the application in other working pressure, please refer to the correction factors.
Model | Pipe size | Flow rates | Dimension (mm) | |||||||
L/S | m³/min | scfm | W(Width) | D(Depth) | H(Height) | A | B | C(clearance for housing) | ||
YF-B010 | RC1/2" | 16.7 | 1.0 | 35.5 | 96 | 79 | 245 | 29 | 180 | 118 |
YF-B020 | RC3/4" | 25.0 | 1.5 | 53.0 | 96 | 79 | 245 | 29 | 180 | 118 |
YF-B030 | RC3/4" | 30.0 | 1.8 | 63.6 | 96 | 79 | 274 | 29 | 209 | 153 |
YF-B040 | RC1" | 33.3 | 2.0 | 71.0 | 96 | 79 | 274 | 29 | 209 | 153 |
YF-B060 | RC1" | 60.0 | 3.6 | 127.0 | 138 | 111 | 349 | 37 | 276 | 208 |
YF-B070 | RC1" | 83.3 | 5.0 | 177.0 | 138 | 111 | 450 | 37 | 377 | 303 |
YF-B080 | RC1-1/2" | 125.0 | 7.5 | 265.0 | 138 | 111 | 450 | 37 | 377 | 303 |
YF-B090 | RC2" | 166.7 | 10.0 | 353.1 | 174 | 142 | 558 | 58 | 500 | 467 |
YF-B100 | RC2-1/2" | 216.7 | 13.0 | 459.0 | 174 | 142 | 558 | 58 | 500 | 467 |
YF-B110 | RC2" | 283.3 | 17.0 | 600.0 | 174 | 142 | 838 | 58 | 780 | 794 |
YF-B120 | RC2-1/2" | 316.7 | 19.0 | 671.0 | 174 | 142 | 838 | 58 | 780 | 794 |
YF-B130 | RC3" | 416.7 | 25.0 | 883.0 | 220 | 184 | 616 | 74 | 542 | 514 |
YF-B140 | RC4" | 466.7 | 28.0 | 989.0 | 220 | 184 | 616 | 74 | 542 | 514 |
YF-B150 | RC3" | 683.3 | 41.0 | 1448.0 | 220 | 184 | 892 | 74 | 798 | 764 |
YF-B160 | RC4" | 800.0 | 48.0 | 1695.0 | 220 | 184 | 892 | 74 | 798 | 764 |
Technical requirements | Maximum operating pressure: 1.6Mpa Maximum operating temperature: 80°C Minimum operating temperature:1.5°C |