Models | HF4850S80-145 | HF4835U80-145 | ||
AC mode | ||||
Rated input voltage | 220/230Vac | 110/120Vac | ||
Input voltage range | (170Vac~280Vac)±2% / (90Vac-280Vac)±2% | (90Vac~140Vac)±2% | ||
Frequency | 50Hz/60Hz(Auto detection) | |||
Parallelable/Split Phase units | Max. parallelable unit: 6pcs | |||
Frequency Range | 47±0.3Hz~55±0.3Hz(50Hz)/57±0.3Hz~65±0.3Hz(60Hz) | |||
Overload/short circuit protection | Circuit breaker | |||
Efficiency | >95% | |||
Conversion time(bypass and inverter) | 10ms(typical) | |||
AC reverse protection | Available | |||
Maximum bypass overload current | 40A | |||
Inverter mode | ||||
Output voltage waveform | Pure sine wave | |||
Rated output power(VA) | 5000 | 3500 | ||
Rated output power (W) | 5000 | 3500 | ||
Power factor | 1 | |||
Rated output voltage(Vac) | 230Vac | 120Vac | ||
Output voltage error | ±5% | |||
Output frequency range (Hz) | 50Hz±0.3Hz/60Hz±0.3Hz | |||
Maximum Efficiency | >92% | >91% | ||
Overload protection | (102%<125%)±10%: report error and turn off the <125%)±10%: report error and turn off theoutput after 5 minutes; (125%<150%)±10%: report error and turnoff the output after 10 seconds; Load >150% ±10%: report error and tun off the output after 5 seconds; | (102%<110%)±10%: report error and turn off the <110%)±10%: report error and turn off theoutput after 5 minutes; (110%<125%)±10%: report error and turn off the output after 10 seconds;(Load >125% ±10%): report error and turn off the output after5 seconds; | ||
Peak power | 10000VA | 6000VA | ||
Loaded motor capability | 4HP | 2HP | ||
Output short circuit protection | Circuit breaker | |||
Bypass breaker specifications | 40A | |||
Rated battery input voltage | 48V(Minimum starting voltage 44V) | |||
Battery voltage range | Undervoltage alarm/shutdown voltage/overvoltage alarm /overvoltage recovery…settable on LCD screen) | |||
Power saving mode | Load ≤50W | |||
AC charging | ||||
Battery type | Lead acid or lithium battery | |||
Maximum charge current | 60A | 40A | ||
Charge curent error | ±5Adc | |||
Charge voltage range | 40Vdc~58Vdc | 40Vdc~60Vdc | ||
Short circuit protection | Circuit breakerand blown fuse | |||
Circuit breaker specifications | 40A | |||
Overcharge protection | Alarm and turn off charging after 1 minute | |||
PV charging | ||||
Maximum PV open circuit voltage | 145Vdc | |||
PV operating voltage range | 60-145Vdc | |||
MPPT voltage range | 60-115Vdc | |||
Battery voltage range | 40-60Vdc | |||
Maximum output power | 4200W | |||
PV charging current range (can be set) | 0-80A | |||
Charging short circuit protection | Blown fuse | |||
Wiring protection Certified specifications | Reverse polarity protection | |||
Certification | CE(EN62040-1) | |||
EMC certification level | EN62040-2, C2 | |||
Operating temperature range | -15℃ to 55℃ | |||
Storage temperature range | -25℃~60℃ | |||
Humidity range | 5% to 95%(Conformal coating protection) | |||
Noise | ≤60dB | |||
Heat dissipation | Forced air cooling, variable speed of fan | |||
Communication interface | USB/RS485(WiFi/GPRS)/Dry node control | |||
Size(L*W*D) | 426*322*124mm | |||
Weight(kg) | 10.8 |