EM motor soft starter is suitable for squirrel cage asynchronous motor control with various loads to ensure reliable start of motor. It has a complete system protection function, extend the service life of the system, reduces the cost of the system, improves the reliability of the system and compatible with various functions of all devices. It is a new ideal alternative for traditional star triangle starter and self-coupling decompression starter.
Product features
Advanced software performance
With intelligent logic, fast complete soft starting process. Parameter can directly calibrate current and voltage displaying value.
Excellent control performance
With voltage and current limiting and etc six starting modes to adapt to different types of load; and soft stop mode to reduce power shock.
Perfect protection function
All series with over current, over voltage, overlord and etc protection functions ,it can effectively guarantee the normal operation of the motor.
Item | Description | ||
---|---|---|---|
Input Power Supply | Input Voltage | Three-phase 480V AC | |
Frequency | 50/60Hz | ||
Adaptive Motor | Squirrel-cage three-phase asynchronous motor | ||
Starting Times | It is recommended not to exceed 20 times per hour. | ||
Control Mode | (1) Operation panel control. (2) Operation panel + external control. (3) External control. (4) External control + COM control. (5) Operation panel + external + COM control. (6) Operation panel + COM control. (7) COM control. (8) No start or stop operation. | ||
Start Mode | (1) Current-limiting to start. (2) Voltage ramp to start. (3) Torque control + current-limiting to start. (4) Torque control + voltage ramp to start. (5) Current ramp to start. (6) Voltage current-limiting double closed-loop start. | ||
Stop Mode | (1) Soft stop. (2) Free stop. | ||
Protective Function | (1) Open loop protection for external instantaneous stop terminals. (2) Over-heat protection for soft starter. (3) Protection for too long starting time. (4) Input open phase protection. (5) Output open phase protection. (6) Unbalanced three-phase protection. (7) starting over current protection. (8) Running overload protection. (9) Under voltage protection for power voltage. (10) Overvoltage protection for power voltage. (11) Protection for fault parameter setting. (12) Load short circuit protection. (13) Auto restart or incorrect wiring protection. (14)Incorrect wiring protection of external control stop terminals. | ||
Ambient | Place to be used | Indoor location with good ventilation free from corrosive gas and conductive dust. | |
Altitude | Below 1000M. It have to rise the rate power when the altitude is more than 1000M. | ||
Temperature | -30 +55 oC | ||
Humidity | 90%RH without dew condensation. | ||
Vibration | <0.5G | ||
Structure | Protection Class | IP20 | |
Cooling Pattern | Natural wind cooling. |
Soft starter model
Model | Power | Current | External Dimensions (mm) | Installation Dimensions (mm) | N.W | ||||||
380V | 480V | (KW) | (A) | H | W | D | H1 | W1 | d | (Kg) | |
EM-GW3-011 | EM-GW4-011 | 11 | 23 | 310 | 150 | 197 | 280 | 85 | M8 | <6 | |
EM-GW3-015 | EM-GW4-015 | 15 | 30 | 310 | 150 | 197 | 280 | 85 | M8 | <6 | |
EM-GW3-018 | EM-GW4-018 | 18.5 | 37 | 310 | 150 | 197 | 280 | 85 | M8 | <6 | |
EM-GW3-022 | EM-GW4-022 | 22 | 45 | 310 | 150 | 197 | 280 | 85 | M8 | <6 | |
EM-GW3-030 | EM-GW4-030 | 30 | 60 | 310 | 150 | 197 | 280 | 85 | M8 | <6 | |
EM-GW3-037 | EM-GW4-037 | 37 | 75 | 310 | 150 | 197 | 280 | 85 | M8 | <6 | |
EM-GW3-045 | EM-GW4-045 | 45 | 90 | 310 | 150 | 197 | 280 | 85 | M8 | <6 | |
EM-GW3-055 | EM-GW4-055 | 55 | 110 | 310 | 150 | 197 | 280 | 85 | M8 | <6 | |
EM-GW3-075 | EM-GW4-075 | 75 | 150 | 370 | 210 | 255 | 330 | 150 | M8 | <12 | |
EM-GW3-090 | EM-GW4-090 | 90 | 180 | 370 | 210 | 255 | 330 | 150 | M8 | <12 | |
EM-GW3-115 | EM-GW4-115 | 115 | 230 | 370 | 210 | 255 | 330 | 150 | M8 | <12 | |
EM-GW3-132 | EM-GW4-132 | 132 | 260 | 505 | 408 | 244 | 450 | 322 | M10 | <23 | |
EM-GW3-160 | EM-GW4-160 | 160 | 320 | 505 | 408 | 244 | 450 | 322 | M10 | <23 | |
EM-GW3-185 | EM-GW4-185 | 185 | 370 | 505 | 408 | 244 | 450 | 322 | M10 | <23 | |
EM-GW3-200 | EM-GW4-200 | 200 | 400 | 505 | 408 | 244 | 450 | 322 | M10 | <23 | |
EM-GW3-250 | EM-GW4-250 | 250 | 500 | 606 | 473 | 263 | 523 | 370 | M10 | <32 | |
EM-GW3-280 | EM-GW4-280 | 280 | 560 | 606 | 473 | 263 | 523 | 370 | M10 | <32 | |
EM-GW3-315 | EM-GW4-315 | 315 | 630 | 606 | 473 | 263 | 523 | 370 | M10 | <32 | |
EM-GW3-355 | EM-GW4-355 | 355 | 710 | 606 | 473 | 263 | 523 | 370 | M10 | <32 | |
EM-GW3-400 | EM-GW4-400 | 400 | 800 | 785 | 647 | 330 | 713 | 560 | M10 | <60 | |
EM-GW3-450 | EM-GW4-450 | 450 | 900 | 785 | 647 | 330 | 713 | 560 | M10 | <60 | |
EM-GW3-500 | EM-GW4-500 | 500 | 1000 | 785 | 647 | 330 | 713 | 560 | M10 | <60 | |
EM-GW3-600 | EM-GW4-600 | 600 | 1200 | 785 | 647 | 330 | 713 | 560 | M10 | <60 |
FAQ
Who are we?
We are based in Guangdong, China, start from 2017,sell to Domestic Market(50.00%),Southeast Asia(12.00%),Eastern Europe(12.00%),South America(5.00%),Eastern Asia(3.00%),Northern Europe(3.00%),Oceania(3.00%),Southern Europe(3.00%),North America(2.00%),Western Europe(2.00%),Mid East(2.00%),Africa(1.00%),South Asia(1.00%),Central America(1.00%). There are total about 51-100 people in our office.
How can we guarantee quality?
EMHEATER frequency inverter passed IEC test and has CE certificate. Each piece of VFD will have 4 testing before delivery, follow ISO 9001 standard. We offer high quality VFD.
Always a pre-production sample before mass production;
Always final Inspection before shipment;
What can you buy from us?
Soft Starter, Frequency Inverter, Servo motor and drive