Specifications
Brand Name :
Zecen
Model Number :
CLIA, POClia
Certification :
ISO 13485, CE, FSC,
Place of Origin :
China, Taizhou
MOQ :
100T (1 BOX),48T (2 BOX)
Price :
Negotiable
Payment Terms :
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :
10000 T/Month/Project
Delivery Time :
10 Days
Packaging Details :
In: Bottle and Strip; Out: Box
Packaging :
reagents bottles, reagents strip
Storage :
2~8℃
CV :
<=8%
Classification :
Tumor Marker
Test throughput :
120+ tests/hour
Calibration :
6 points
Control :
2 points
Description

Tumor Marker CYFRA 21 Cytokeratin 19 Fragment for Fully Automatic Immunoassay Analyzer IVD Reagents 100T/box,24T/box

INTENDED USE

The kit has been designed for the quantitative determination of Cytokerantin-19-fragment (CYFRA21-1) in human serum.

The method can be used for samples over the range of 0.1-500.0ng/mL.

The test has to be performed on the CIA fully auto analyzer (Including CIA 600, CIA 1200, CIA 1800, CIA2800).

KIT COMPONENTS

Material Supplies

Reagent Integral for 50 determinations
Magnetic beads: magnetic beads complex binding with goat anti-FITC, buffer with BSA 1×1.5mL
Calibrator Low: BSA buffer with low level of CYFRA21-1 antigen 1×0.3mL
Calibrator High: BSA buffer with high level of CYFRA21-1 antigen 1×0.3mL
CYFRA21-1 Anti A: CYFRA21-1 Antibody complex labeled FITC and CYFRA21-1 Antibody complex labeled by AP, containing buffer with BSA 1×3.0mL
All reagents are provided ready-to-use.

Reagent Integral for 100 determinations
Magnetic beads: magnetic beads complex binding with goat anti-FITC, buffer with BSA 1×3.0mL
Calibrator Low: BSA buffer with low level of CYFRA21-1 antigen 1×0.3mL
Calibrator High: BSA buffer with high level of CYFRA21-1 antigen 1×0.3mL
CYFRA21-1 Anti A: CYFRA21-1 Antibody complex labeled FITC and CYFRA21-1 Antibody complex labeled by AP, containing buffer with BSA 1×6.0mL
All reagents are provided ready-to-use.

Reagent Vials in kit box
Control 1: BSA buffer with low level of CYFRA21-1 Antigen 1×0.3mL
Control 2: BSA buffer with high level of CYFRA21-1 Antigen 1×0.3mL
target value refer to Quality Control sheet

Accessories Required But Not Provided

Substrate REF: SR2001
System cleaning solution REF: WR2001
Probe cleaning solution REF: WR2002

Tumor Marker CYFRA 21 Cytokeratin 19 Fragment for Fully Automatic Immunoassay Analyzer IVD Reagents 100T/box,24T/box

Send your message to this supplier
Send Now

Tumor Marker CYFRA 21 Cytokeratin 19 Fragment for Fully Automatic Immunoassay Analyzer IVD Reagents 100T/box,24T/box

Ask Latest Price
Brand Name :
Zecen
Model Number :
CLIA, POClia
Certification :
ISO 13485, CE, FSC,
Place of Origin :
China, Taizhou
MOQ :
100T (1 BOX),48T (2 BOX)
Price :
Negotiable
Contact Supplier
Tumor Marker CYFRA 21 Cytokeratin 19 Fragment for Fully Automatic Immunoassay Analyzer IVD Reagents 100T/box,24T/box
Tumor Marker CYFRA 21 Cytokeratin 19 Fragment for Fully Automatic Immunoassay Analyzer IVD Reagents 100T/box,24T/box

Taizhou Zecen Biotech Co.,Ltd.

Active Member
3 Years
jiangsu, taizhou
Since 2011
Business Type :
Manufacturer
Employee Number :
300~500
Certification Level :
Active Member
Contact Supplier
Submit Requirement