Specifications
Brand Name :
GFUVE
Model Number :
GF106T-1000A
Certification :
CE, UL, ISO9001, KEMA
Place of Origin :
BEIJING CHINA
MOQ :
1set
Price :
USD10000-20000/set
Payment Terms :
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :
200sets
Delivery Time :
1-2weeks
Packaging Details :
standard export wooden box
NAMES :
Instrument Current Transformer calibration
APPLICATION :
TEST CURRENT TRANSFOREMR ERROR
RATIO :
1-5000
PHASE :
4 min
ACCURACY :
0.2%
Weight :
22kg
1000A cable :
4m length
Display LCD :
6.4 inch
Description

Portable Instrument Current Transformer Calibration Device With Turn Ratio 5000/1 To 25000/5A

GF106T Portable Instrument Current Transformer calibration Device with turn ratio 5000/1 to 25000/5A

GF106T Portable Instrument Current Transformer calibration device is mainly used for field testing of P class CT and PT. The test items mainly include excitation characteristic, transformation ratio, polarity, degauss, 5% and 10% error curves, secondary circuit check, withstand test of power frequency alternating current and secondary load. Adopting LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data, with simple and convenient operation.

MAIN FUNCTIONS

I. Current Transformer (CT) II. Voltage Transformer (PT)
1. Magnetization curve 1. Excitation characteristic test
2. Transformation ratio test 2. Transformation ratio test
3. Polarity 3. Polarity
4. 5% and 10% error curve 4. Withstand test of power frequency alternating current
5. Current Injecting 5. Degauss
6. Degauss 6. Calculation of knee point value
7. Withstand test of power frequency alternating current 7. Actual secondary load test 
8. Automatic calculation of excitation knee
point value
8. Resistance test
9. Actual secondary load test 
10. Resistance test 

PARAMETERS

Electrical parameters
Accuracy 0.2%, 0.5%
Power supply AC 220V±10% or AC 110V±10%, 50/60Hz
Excitation voltage output 0-2500Vrms,
Excitation current output 0-5Arms (20A peak-value)
Large current output 0-1000A
Electrical parameters - continued
Accuracy ≤0.5% (0.2%RD+0.3%RG)
Secondary winding DC resistance measurement Range 0.1-300Ω
Accuracy ≤0.5% (0.2%RD+0.3%RG)
Secondary actual load measurement Range 5VA-1000VA
Accuracy ≤0.5% (0.2%RD+0.3%RG)±0.1VA
CT/PT phase error measurement Accuracy ±4min
Resolution 0.01min
CT ratio error measurement Range ≤25000A/5A(5000A/1A)
Accuracy ≤0.5%
PT ratio error measurement Range 1-500KV
Accuracy ≤0.5%
Standards 
Reference standards GB1207-2006, GB1208-2006, GB16847-1997
IEC60044-1, IEC60044-6, IEC61869-2-2012
Safety standards GB 4793.1-2007
EMC EMC standard 89/336/EEC
FCC Subpart B of Part 15 Class A
IEC 1000-4-2 /3 /4 /6
Mechanical parameters 
Overall dimension (L x W x H) (mm) 400 x 250 x 250
Weight (kg) ≤22
Environmental conditions 
Relative humidity 90RH%
Operating temperature -10°C to +40°C
Altitude ≤1000m

Portable Instrument Current Transformer Calibration Device With Turn Ratio 5000/1 To 25000/5A

Send your message to this supplier
Send Now

Portable Instrument Current Transformer Calibration Device With Turn Ratio 5000/1 To 25000/5A

Ask Latest Price
Brand Name :
GFUVE
Model Number :
GF106T-1000A
Certification :
CE, UL, ISO9001, KEMA
Place of Origin :
BEIJING CHINA
MOQ :
1set
Price :
USD10000-20000/set
Contact Supplier
Portable Instrument Current Transformer Calibration Device With Turn Ratio 5000/1 To 25000/5A
Portable Instrument Current Transformer Calibration Device With Turn Ratio 5000/1 To 25000/5A
Portable Instrument Current Transformer Calibration Device With Turn Ratio 5000/1 To 25000/5A
Portable Instrument Current Transformer Calibration Device With Turn Ratio 5000/1 To 25000/5A

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

Active Member
8 Years
beijing, beijing
Since 2008
Business Type :
Manufacturer
Total Annual :
$100,000,000-$150,000,000
Employee Number :
300~350
Certification Level :
Active Member
Contact Supplier
Submit Requirement