Specifications
Brand Name :
GFUVE
Model Number :
GF102 - 1
Certification :
ISO
Place of Origin :
China
MOQ :
1 Pieces
Price :
Negotiable
Payment Terms :
T/T, Western Union,Paypal
Supply Ability :
500 Pieces Per Month
Delivery Time :
3 - 7 Days
Packaging Details :
Standard Export Wooden Box
Power supply :
One Phase AC 100-265V, frequency 50/60Hz.
Frequency Output Adjustment range :
40Hz-70Hz
Meter under testing :
1P2W
Accuracy class :
0.05%, 0.1%
Power Factor Adjustment range :
-1 ~ 0 ~ 1
LCD :
7inch Touch TFT Color LCD
Description

Portable Single Phase Energy Meter Test Equipment

1 . Meter under testing: 1P2W
2 . Testing mode: active power, reactive power
3 . Test 3pcs or 2pcs meter synchronously
4 . Start testing and creep testing
5 . Reference standard and power source integrated, easy to carry
6 . Measuring mechanical meter and electric meter
7 . Operating by manual keyboard or PC software
8 . With keyboard shortcuts
9 . Internal large capacity storage device for mass memory
10 . Local checking the testing result
11 . Overload, short circuit, open circuit protection
12 . With self-checking function

Parameters

Electrical parameters  
Accuracy class 0.05%, 0.1%
Power Supply One Phase AC 100-265V, frequency 50/60Hz.
AC Voltage Output  
Range 57.7V, 100V, 220V, 380V; max 500V
Adjustment range (0-120)%RG(1)
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability 0.01%/120s
Distortion 0.2% (Non-capacitive load)
Output load max 25VA
Measuring accuracy 0.05%RG
AC Current Output  
Range 200mA, 1A, 5A, 20A, 60A(100A) optional; max 120A
Adjustment range (0-120)%RG
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability <0.01%/120s
Distortion ≤0.2% (Non-capacitive load)
Output load max 50VA
Accuracy 0.05%RG
Power Output  
Active power output stability <0.01%RG/120s
Reactive power output stability <0.02%RG/120s
Active power measuring accuracy 0.05%RG
Reactive power measuring accuracy 0.1%RG
Phase Output  
Output adjustment range 0°-359.999°
Output adjustment fineness 10, 1, 0.1, 0.01 as optional.
Resolution 0.01°
Accuracy 0.05°
Power Factor  
Adjustment range -1 ~ 0 ~ 1
Resolution 0.0001
Measurement accuracy 0. 0005
Frequency Output  
Adjustment range 40Hz-70Hz
Output adjustment fineness 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional.
Resolution 0.001Hz
Accuracy 0.005Hz
Voltage /Current/Harmonic Setting  
Harmonic number 2-51times
Harmonic content 0-40%
Harmonic phase 0-359.99
Harmonic setting accuracy (10%±0.1%)RD(2)
Power Energy Measurement Error  
Active power energy 0.05%RG
Reactive power energy 0.1%RG
Power Pulse Output  
Power pulse type active pulse, reactive pulse
Active power pulse output 5V, 10mA
Power Pulse Input  
Energy pulse type support active and reactive pulse, the highest frequency power pulse input is 180K.
Mechanical parameters  
Dimensions (W×D×H) (mm) 455x440x150
Weight (kg) 12
(1) RG means range, the same as below;
(2) RD means the setted harmonic content, harmonic can be a single output, also multiple output.

The product picture:

GF102 Portable Portable Meter Test Equipment , Energy Meter Testing Equipment

Send your message to this supplier
Send Now

GF102 Portable Portable Meter Test Equipment , Energy Meter Testing Equipment

Ask Latest Price
Brand Name :
GFUVE
Model Number :
GF102 - 1
Certification :
ISO
Place of Origin :
China
MOQ :
1 Pieces
Price :
Negotiable
Contact Supplier
GF102 Portable Portable Meter Test Equipment , Energy Meter Testing Equipment
GF102 Portable Portable Meter Test Equipment , Energy Meter Testing Equipment