Specifications
Brand Name :
GFUVE
Model Number :
Q40-3
Certification :
CE UL
Place of Origin :
China
MOQ :
1
Price :
Negotiable
Payment Terms :
T/T, Western Union, L/C, MoneyGram, D/P, D/A
Supply Ability :
5000 pieces per month
Delivery Time :
Within 7 Days
Packaging Details :
Export Carton Box
Ratio :
1000: 1 customize
Accuracy :
0.2%, 0.5%
Primary current :
500A
Secondary current :
0 - 1A AC or 0-5V AC (customized)
Output signal (AC voltage) :
250mV, 500mV, 1V, 5V AC at nominal input current
Frequency range :
40Hz-10MHz
Names :
AC Clamp On Current Transformer
Application :
Phase angle meter & power meter
Description




Q40 Ratio 500A / 500mA Split Core Amp Current Sensor for Metering 40mm 0.5 Class


The GFUVE Split Core Amp Current Sensor Q40-3 features 40 mm jaw size and distinct jaw shapes which can hook around the conductor easily. Q40-3 sensors are an excellent probe to be used in power and low level current measurement applications.

A common form of current clamp comprises a split ring made of ferrite or soft iron. A wire coil is wound round one or both halves, forming one winding of a current transformer. The conductor it is clamped around forms the other winding. Like any transformer this type works only with AC or pulse waveforms, with some examples extending into the megahertz range.

Clamp-on Current Transformer Current Clamp is a high-precision AC current converter, and can meet a variety of measuring instruments, It can be used along with many kinds of instruments and devices, such as energy meter spot calibrator, multifunctional meter, oscilloscope, digital multimeter, dual clamp Ground resistance tester, dual clamp phase volt ammeter.

The GFUVE clamp-on current transformer is very popular with our customers due to its fast and easy installation Produced with amorphous silicon core or permalloy core, this product features small size, high precision good stability and good anti-interference This product is widely used for measuring power and energy in the fields of electric power, communication and monitoring system. Besides the high precision and the small phase error this clamp-on current transformer can be used to measure a wide variety of electric parameters without disconnecting the exiting electric system.

Features
Measurement range of 1mA to 600A AC
Large jaw opening designed
Improved ergonomic design and easy operation
High content nickel metal core
Conforms to EN 61010, 600V CAT III
Low phase shift for power measurement
Designed for DMMs, recorders, loggers, oscilloscopes, power and harmonic meters
UL, CE mark

Applications
Power quality measuring
Large industrial loads
Measuring around cable bundles
Power load monitoring
Waveform analysis
Energy meter calibrator

Parameter

Electrical parameters
Ratio 1000: 1 or 2000:1 (customized)
Accuracy class 0.1%, 0.2%, 0.5%
Primary current 0 - 500A AC
Secondary current 0 - 1A AC or 0-5V AC (customized)
Max. Cont. Input current 600A
Over voltage category CAT III 600V
Output signal (AC current) 250mA,500mA,1A,5A AC at nominal input current
Output signal (AC voltage) 250mV, 500mV, 1V, 5V AC at nominal input current
Frequency range 40Hz-2000Hz
Dielectric strength 3KV 50Hz/60Hz at 1 minute
Temperature range -20°C to +55°C
Output 2.5 meter cable with D01 connector
Max. voltage not insulated conductors 600 V
Standard EN 61010-1, EN 61010-2-032, IEC60044-1
Installation Clamp type
Output mode Lead output (2.5m)
Mechanical parameters
Dimensions (L x W x H) (mm) 82 x 290 x 25.3
Weight (g) 500
Holding wire diameter (mm) φ40
Max. jaw opening (mm) 40
Color Black
Material PC+ABS+Polycarbonate, UL94 V0

Q40V1-500 500A 600A 1V 1000:1 customized 0.2%
Q40V2-500 500A 600A 2V 1000:1 customized 0.2%
Q40V4-500 500A 600A 4V 1000:1 customized 0.2%
Q40V5-500 500A 600A 5V 1000:1 customized 0.2%
Q40V10-500 500A 600A 10V 1000:1 customized 0.2%

Photos
10M Hz Ratio 500A / 500mA AC Current Clamp On Current Transformer busbar Jaw Opening
10M Hz Ratio 500A / 500mA AC Current Clamp On Current Transformer busbar Jaw Opening
FAQ, following questions will help you to select the matched probe for your applications.
1. Please determine if you are measuring AC or DC?
GFUVE Q40-3 is for AC metering.

2. What is the maximum current you will measure?
Q40-3 has 600A as max.

3. What size conductor will you clamp onto? This parameter determines the probe jaw size needed.
Q40-3 conductor diameter is 40mm

4. What type of probe output do you need or can you work with (mA, mV, A, AC, etc.)?
Q40-3 can customize output with Ampere, Volt.

5. What is the working voltage of the conductor to be measured?
GFUVE probes should be used below 600 volts

6. What type of termination do you need: jacks, leads or BNC?
Q40-3 standard has 2.5meter leads. We can offer jacks or BNC… as options.

7. If you cannot find information you need or would like assistance, contact us today. We have designed many more probes than those shown in this catalog, and we manufacture in Beijing, China.

Send your message to this supplier
Send Now

10M Hz Ratio 500A / 500mA AC Current Clamp On Current Transformer busbar Jaw Opening

Ask Latest Price
Watch Video
Brand Name :
GFUVE
Model Number :
Q40-3
Certification :
CE UL
Place of Origin :
China
MOQ :
1
Price :
Negotiable
Contact Supplier
video
10M Hz Ratio 500A / 500mA AC Current Clamp On Current Transformer busbar Jaw Opening
10M Hz Ratio 500A / 500mA AC Current Clamp On Current Transformer busbar Jaw Opening
10M Hz Ratio 500A / 500mA AC Current Clamp On Current Transformer busbar Jaw Opening
10M Hz Ratio 500A / 500mA AC Current Clamp On Current Transformer busbar Jaw Opening

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

Active Member
8 Years
beijing, beijing
Since 2008
Business Type :
Manufacturer
Total Annual :
$100,000,000-$150,000,000
Employee Number :
300~350
Certification Level :
Active Member
Contact Supplier
Submit Requirement