TEST-630 portable auto six phase protective relay test equipment for ABB, Schneider & Siemens protection relay device
The proper operation of the protective relays is critical in the reliability and safety of power systems, protecting other devices from damage and helping to the system security. Accordingly, the testing of relays is required during the installation and commissioning process, and as part of the maintenance programs throughout its service life.
Protection testing. Protection systems play a key role for the safe and reliable operation of today’s electricity power systems. Properly working protection devices help to maintain the safety of the system and to safeguard assets from damage. In order to ensure reliable operation, protective relays as well as recloser controls must be tested throughout their life-cycle, from their initial development through
Protection systems play a key role for the safe and reliable operation of today’s electricity power systems. Properly working protection devices help to maintain the safety of the system and to safeguard assets from damage. In order to ensure reliable operation, protective relays as well as recloser controls must be tested throughout their life-cycle, from their initial development through production and commissioning to periodical maintenance during operation.
Our test equipment is ideal for each of these life-cycle phases and for any environment. As a reliable long-term partner, we offer state-of-the-art testing solutions which are continuously being developed and maintained to help you to keep pace with the increasingly complex requirements of your systems.
Relays testing may range from a simple check of some points of the relay characteristic to a complete verification of the protection scheme logic, even including the response to transient waveforms, harmonics, etc
TEST-630 is designed with fuse on the mains supply and electronic protection for overload on the current (open circuit) or voltage outputs(short circuit), with immediate isolation of the output and alarm indication. Also diagnostic message for the setting of wrong data, mistakes on the input etc. There's also electronic protection in case of counter-feed of voltage output, if any incorrectness happen, the alarm light shall flash. And Overheat LED indicator shall flash for Protection against over-temperature, on all outputs.Universal testing system TEST-630 (6×35A, 6×300V) can test all types of protective relays, including modern IEC61850 based relays. Other test works, such as transducer, energy meter, indication meter, etc., can also be done easily. It's the ideal test
device for all power utilities, power plants, relay manufactures, panel manufactures, research institutes, Universalities, testing
companies, etc.
Differential
is suitable for use the 6 output current channels' relay tester, which is applied on transformer, generator and bus bar etc. differential protection equipment test. Because of adopting the 6 currents output, it realizes the two sides three phases test between relay tester and relay equipment.
Inverse time overcurrent
This module realizes the directional over-current test and non-directional over-current test. This module also include: testing positive sequence, negative sequence and zero sequence instantaneous time over-current,
over-heat protection inverse time over-current or the customized “Current/Time” operation characteristic.
TEST ITEM
- U/I test
- DC test
- Impedance characteristics
- Power direction test
- I-T test
- Differential relay
- Harmonic test
- Differential protection
- Distance protection
- Zero sequence protection
- Setting group test
- State sequence
- Synchronization test
- Special test
- Oscillation test
- Metering instrument
- Hardware checkout
- Low Voltage protection
- Fault Recurrence
PARAMETERS
Electrical parameters |
Power voltage | AC220V±10% or AC110V±10%, 50/60Hz±10% |
Time measurement | 0.1ms-999999.999s |
AC current output |
Phase current output (effective value) | 6 x 0-30A |
Maximum power output | 260VA/phase |
Maximum parallel current output (effective value) | 0-180A |
Long-term allowable working value of phase current (effective value) | >10A |
Allowable working time of maximum current | >11s |
Accuracy class | <±0.1% |
AC voltage output |
Phase voltage output (effective value) | 6 x 0-130V |
Line voltage output (effective value) | 0-260V |
Maximum power output | 70VA/phase |
Accuracy class | <±0.1% |
DC current output |
Output range | -10 to 10A or 3 x 0 to ±10A |
Maximum power output | 200VA |
Accuracy class | <±0.1% |
DC voltage output |
Output range | 0-300V or 5 x 0 to ±130V |
Maximum output power | 130VA |
Accuracy class | <±0.1% |
Binary input |
Idle contact | 1-20mA, 24V (DC) |
Electric potential contact | 250V/0.5A (DC) |
Binary output |
Idle contact | 250V/0.5A (DC) |
Rated output |
Frequency error | <±0.01Hz |
Phase error | <±0.1° |
Waveform distortion | <±0.3% (fundamental wave) |
Time error | <40µs |
Output frequency | 0-1050Hz |
Superposed harmonic wave | 0-21times |