Specifications
Brand Name :
GFUVE
Model Number :
LZCK-55
Certification :
IEC60044-1;IEC61869-2;ANSI C57.13;GB1208-2006;NTC2250
Place of Origin :
CHINA
MOQ :
10
Price :
USd /$85-$120 /PC
Payment Terms :
T/T
Supply Ability :
10000Pcs/month
Packaging Details :
standard package
Accuracy class :
0.5S,0.5%,1%,3%
Range of primary rated current :
100-1500A
Rated load :
≤10VA
Rated secondary current :
5A,1A
Output signal :
1A,5A,333mV,1V,5V(customized)
Color :
Orange or black
Aperture(mm) :
55
Cable length :
2.5m,5m,10m(customized)
Dimensions(mm) :
180x138x52
Weight(kg) :
2
Rated short-time thermal current :
40KA,1S
Rated continuous thermal current :
150%|1n
Safety factor rating :
(FS)<10
Description

Outdoors waterproof 1500A medium voltage Φ55 permalloy split core current transformer

LZCK series current transformers are applicable for AC power system 35kV and measurement of current of power supply equipment below 10KV also can be used for microcomputer protection. This type of current transformer employs imported silicon steel which with high permeability as magnetic material, has the characteristics of Small magnetic circuit loss and can be split, its semicircular core and secondary windings employ high quality epoxy resin vacuum, casting in plastic-case which is flame retardance anti-moisture, stable performance, no maintenance.

Outdoor Waterproof Split Core Current Transducer 1500A Medium Voltage

Parameters

Technical parameters
Standards

IEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006;

ANSI C57.13

Accuracy Class 0.5S, 0.5%, 1%, 3%
Range of primary rated current 100-1500A

Range of Rated load ≤10VA
Rated frequency 50/60Hz
Rated secondary current 5A or 1A
Rated short-time thermal current 40kA, 1S
Rated continuous thermal current 150%I1n
Secondary winding power frequency withstand voltage 3kV, 1min
Safety Factor Rating (FS) <10
Output signal 1A, 5A, 333mV, 1V or 5V(customized)
Cable length 2.5m, 5m, 10m(customized)

Flame retardant ABS plastic shell inside, jaw waterproof apron.

Mechanical parameters

Aperture (mm) Φ55
Dimensions (W×D×H) (mm) 180×138×52
Weight (kg) 2
Working conditions
Operating temperature -35°C to +65°C, average not exceeding +40°C
Storage temperature -40°C to +70°C
Ingress Protection IP65
Environment outdoors or indoors
The Height of above sea level 0- 3000m
Conditions

No existence of severely begrimed, erosive and

radioactive gas in the air. Continuous working under the rated current is allowed.

Send your message to this supplier
Send Now

Outdoor Waterproof Split Core Current Transducer 1500A Medium Voltage

Ask Latest Price
Brand Name :
GFUVE
Model Number :
LZCK-55
Certification :
IEC60044-1;IEC61869-2;ANSI C57.13;GB1208-2006;NTC2250
Place of Origin :
CHINA
MOQ :
10
Price :
USd /$85-$120 /PC
Contact Supplier
Outdoor Waterproof Split Core Current Transducer 1500A Medium Voltage
Outdoor Waterproof Split Core Current Transducer 1500A Medium Voltage
Outdoor Waterproof Split Core Current Transducer 1500A Medium Voltage
Outdoor Waterproof Split Core Current Transducer 1500A Medium Voltage
Outdoor Waterproof Split Core Current Transducer 1500A Medium Voltage
Outdoor Waterproof Split Core Current Transducer 1500A Medium Voltage

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

Active Member
8 Years
beijing, beijing
Since 2008
Business Type :
Manufacturer
Total Annual :
$100,000,000-$150,000,000
Employee Number :
300~350
Certification Level :
Active Member
Contact Supplier