Specifications
Brand Name :
GFUVE
Model Number :
GF211B
Certification :
CE,ISO9001:2008,IEC
Place of Origin :
China Beijing
MOQ :
1Set
Price :
US$1000~US$1200/Set
Payment Terms :
Western Union, T/T, L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :
1000Sets/Month
Delivery Time :
3days
Packaging Details :
Standard export box
Accuracy :
0.5%
GF211B :
Digital Phase Angle Meter
AC Voltage :
0~500V
AC Current :
0-10A
Characteristics :
Handheld
Current clamps :
2pcs(10A)
Phase range :
0-360.0°
LCD :
2.8 inch Green LCD
Description

10A 500v Double Clamp Digital Phase Angle Meter For Electronic Test Equipment

GF211B 10A 500v High Precision Double Clamp Digital Phase Angle Meter for protection deivce and Metering equipment

(Accuracy 0.5%)

Application

GF211B Handheld double clamp digital phase angle meter is a multi-functional portable instrument. It is an ideal choice for electric power bureau, factories, mine, petroleum-chemistry enterprises, metallurgy factories and so on.

Phase-Angle Meter. an instrument used to measure the cosine of the phase-shift angle, or the power factor, between voltage and current in electric AC circuits at frequencies specified for mains used by industry or to measure the phase difference of electric oscillations.

Phase angle meters measure magnitudes AND angles based on a reference angle. Can you guess what the phase angle meter would measure in the following figure? The phase angle meter would measure 100V, but the angle will be a random number that might change constantly because the phase angle meter does not have a reference.
Phase-Angle Meter. The measuring mechanism in such meters is a ratio meter of the electrodynamic, ferrodynamic, electromagnetic, or induction type; the deflection of the moving part of the ratio meter depends on the phase shift between the given voltage and current. Electronic counters are used as phase-angle meters for a wide range of frequencies.

FEATURES

  • Measure phase angle between two voltages, between two current or between voltage and current
  • Measure alternating voltage (U), alternating current (I), frequency (F), active power (P), reactive power (Q), power factor (PF) and so on.
  • Current signal is obtained by the clamp current transformer on line directly
  • Discern inductive circuit and capacitive circuit;
  • Directly read differential protection phase among every unit of CT
  • Can check connection of transformer
  • Measure two way voltage phase sequence
  • Can check whether the meter connection is right or not
  • Can evaluate the running speed of electric kWh meter
  • High resolution of current, so can be used as a leakage current meter

Phase angle meter. It is capable of displaying the phase angle relationship between two power signals, which can be two currents, two voltages or any combination. Currents up to 10 A and voltages up to 500 V can be applied directly to the instrument. The current input range can be extended by using external current transformers.

PARAMETERS

Electrical parameters 
Accuracy class 0.5%
Power supply 3.7V batteries
Scale 
Phase 0-360.0°
AC Voltage 0-500V
AC Current 200mA / 2A / 10A
Frequency 45-65Hz
Active power accuracy 0.5%, resolution 0.01W
Power factor -1 ~ 0 ~ 1, resolution 0.001
Fundamental error (under standard operating environment)
Temperature 23°C±5°C
Moisture <65%
Wave form Sine wave Distortion ≤1%
Frequency 50±2Hz, 60±2Hz
Wire position Center of clamp
Phase measurement Voltage: 100V±25V
Current: 1A±0.2A
Phase accuracy 0.5% FS
Voltage accuracy 
200V 0.5FS, Resolution 0.1V
500V 0.5FS, Resolution 1V
Current accuracy 
10A 0.5FS, Resolution 10mA
2A 0.5FS, Resolution 1mA
200mA 1.0FS, Resolution 0.1mA
Input impedance 
When measure voltage 1MΩ
Input voltage impedance >120KΩ when measure phase
Phase measurement 
Voltage range 2-500V
Current range 0.002-10A
Additional error 
Measure phase angle, the voltage and the current Less than the fundamental error
Measure current The error led by wires away from center of clamps is less than the fundamental error
Safety specification  
Resistance to voltage The meter can resist 1000V (AC sine wave, 50Hz or 60 Hz) for 1 minute between the meter circuit and the meter case; Between input joint U1 and U2 can resist 500V (AC sine wave, 50Hz or 60 Hz) for 1 minute.
Insulation resistance The resistance both between the meter circuit and the meter surface and between the terminals U1 and U2 is greater than 100MΩ.
Mechanical parameters 
Dimensions (W×D×H) (mm) 185×85×41
Weight (kg) 0.26
Environmental conditions 
Working temperature 0°C±40°C
Humidity ≤80%
Accessory 
Multi-function double clamp digital phase angle meter 1 piece
Clamps 10A 2 pieces
Clamp wire 2 pieces
Voltage wire 2 pieces
User's manual 1 piece
Certification of quality 1 piece
Box 1 piece

Photo

10A 500V High Precision Portable Meter Test Equipment Double Clamp Digital Phase Angle Meter

Send your message to this supplier
Send Now

10A 500V High Precision Portable Meter Test Equipment Double Clamp Digital Phase Angle Meter

Ask Latest Price
Brand Name :
GFUVE
Model Number :
GF211B
Certification :
CE,ISO9001:2008,IEC
Place of Origin :
China Beijing
MOQ :
1Set
Price :
US$1000~US$1200/Set
Contact Supplier
10A 500V High Precision Portable Meter Test Equipment Double Clamp Digital Phase Angle Meter
10A 500V High Precision Portable Meter Test Equipment Double Clamp Digital Phase Angle Meter
10A 500V High Precision Portable Meter Test Equipment Double Clamp Digital Phase Angle Meter
10A 500V High Precision Portable Meter Test Equipment Double Clamp Digital Phase Angle Meter

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

Active Member
8 Years
beijing, beijing
Since 2008
Business Type :
Manufacturer
Total Annual :
$100,000,000-$150,000,000
Employee Number :
300~350
Certification Level :
Active Member
Contact Supplier