Specifications
Brand Name :
GFUVE
Model Number :
GF312V2
Place of Origin :
BEIJING,CHINA
MOQ :
1500SETS
Payment Terms :
T/T, Western Union, MoneyGram
Supply Ability :
1500SETS/MONTH
Delivery Time :
1-2WEEKS
Packaging Details :
CARTON
ACCURACY :
0.05%, 0.1%
POWER SUPPLY :
External power, 220V/110V, 50/60Hz
VOLTAGE RANGE :
30-560V
CURRENT RANGE :
0.01-10A
HARMONIC :
2nd-51st
FREQUENCY :
45Hz-65Hz
DIMENSION :
245×168×70 MM
WEIGHT :
1.8KG
RESOLUTION :
7” TFT color (480×234)
Description

High Accuracy And Quality Watt-Hour Meter Calibraotr,New Product And Hot Sale

INTRODUCTION

The device is equipped with thigh resolution TFT color LCD. The Reference Standard is used to test single and three phase meters, instrument transformers and installations on site.The unit can be used with various types of clamp-on CTs and current and voltage sensors. Therefore, it is possible to easily and accurately test both CT/PT and direct connected meters.The GF312V2 electronic working standard is a precision measurement unit for all AC values that are used in the measurement of energy. It impressive trough its small dimensions and light weight. The wide measurement range, high precision and excellent immunity to interference are the outstanding features of this instrument.

PARAMETERS

Accuracy class 0.05%, 0.1%
Power Supply External power, 220V/110V, 50/60Hz
Phase voltage supply 45-450V, 50/60Hz
Li-Battery supply
Voltage measurement 
Range 30-560V
Error ±0.05%
Harmonic 2nd-51st
Current measurement 
Range (direct connection) 0.01-10A
Range (clamp CT) 5A,100A,500A,1000A,2000A (option)
Error (direct connection) ±0.05%
Error (clamp CT) ±0.2% (5A, 100A )
±0.5% (other)
Harmonic 2nd-51st
Power measure error 
Active power (direct connection) ±0.05%
Active power (clamp CT) ±0.2% (5A, 100A)
±0.5% (other)
Reactive power (direct connection) ±0.1%
Reactive power (clamp CT) ±0.2% (5A, 100A)
±0.5% (other)
Energy measure error 
Active energy (direct connection) ±0.05%
Active energy (clamp CT) ±0.2% (5A, 100A)
±0.5% (other)
Reactive energy (direct connection) ±0.1%
Reactive energy (clamp CT) ±0.2% (5A, 100A)
±0.5% (other)
Phase angle 
Range 0°-360°
Resolution 0.01°
Error ±0.05°
Frequency 
Range 45Hz-65Hz
Resolution 0.001Hz
Error 0.002Hz
Pulse output 
Energy constant 25000
Pulse ratio 1:1
Output level 5V
Pulse input 
Input channel 2
Input level 5-10V
Input frequency Max. 100Hz
Display 
Resolution 7” TFT color (480×234)
Function 
Vector diagram Yes
Waveform Yes
Energy accumulation Yes
CT ratio test Yes
Local parameter input Yes
Wiring emulation Yes
Self-calibration Yes
Recorder check Yes
Data storage Yes
Data storage qty 5000
External extend memory Yes
Screen printing Yes
Communication port USB/RS232
Communication with PC Yes
Upload data Yes
External mini printer Yes
External keyboard Yes
Mechanical parameters 
Dimensions (W×H×D) (mm) 245×168×70
Weight (kg) 1.8
Environmental conditions 
Ambient temperature -25°C to +45°C
Relative humidity 30%-95%

Calibration Watt Hour Meter Energy Measurement 560V 65Hz

Send your message to this supplier
Send Now

Calibration Watt Hour Meter Energy Measurement 560V 65Hz

Ask Latest Price
Brand Name :
GFUVE
Model Number :
GF312V2
Place of Origin :
BEIJING,CHINA
MOQ :
1500SETS
Payment Terms :
T/T, Western Union, MoneyGram
Supply Ability :
1500SETS/MONTH
Contact Supplier
Calibration Watt Hour Meter Energy Measurement 560V 65Hz
Calibration Watt Hour Meter Energy Measurement 560V 65Hz
Calibration Watt Hour Meter Energy Measurement 560V 65Hz
Calibration Watt Hour Meter Energy Measurement 560V 65Hz

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

Active Member
8 Years
beijing, beijing
Since 2008
Business Type :
Manufacturer
Total Annual :
$100,000,000-$150,000,000
Employee Number :
300~350
Certification Level :
Active Member
Contact Supplier
Submit Requirement