ZONCN T9000 Series Advanced Vector Control Inverter
Item | Description | |||
Basic function | Control Mode | VF control | ||
Sensorless flux vector control(SVC) | ||||
Close-loop vector control(FVC)(Above 3.7kW) | ||||
Maximum frequency | 0~600Hz | |||
Carrier frequency | 0.5kHZ——8kHz | |||
The carrier frequency is automatically adjusted based on the load features | ||||
Input frequency resolution | Digital setting:0.01Hz | |||
Analog setting: Maximum frequency x 0.025% | ||||
Start torque | G Type:0.5Hz/150%(SVC) | |||
P Type:0.5Hz/100% | ||||
Speed range | 1:100 (SVC) | |||
Speed stability accuracy | ±0.5%(SVC) | |||
Overload capacity | G Type:60s for 150% of the rated current, 3s for 180% of the rated current. P Type:60s for 120% of the rated current, 3s for 150% of the rated current. | |||
Torque boost | Auto-boost ; | |||
Customized boost: 0.1%~30.0% | ||||
V/F Curve | Straight-line V/F curve | |||
Multi-point V/F curve | ||||
N-power V/F curve (1.2-power, 1.4-power, 1.6-power, 1.8-power, square) | ||||
V/F separation | 2 types: complete separation; half separation | |||
Ramp Mode | Straight-line ramp. | |||
Four groups of acceleration/deceleration time with the range of 0.00`6500.0s | ||||
DC braking | DC braking frequency:0.00Hz~Maximum frequency | |||
Braking time:0.0s~36.0s | ||||
Braking action current value:0.0%~100.0% | ||||
JOG control | JOG frequency range:0.00Hz~50.00Hz | |||
JOG acceleration/deceleration time: 0.0s~6500.0s. | ||||
Simple PLC,Multiple preset speeds | It implements up to 16 speeds via the simple PLC function or combination of terminal states | |||
Onboard PID | It realizes process-controlled closed loop control system easily | |||
Auto voltage regulation(AVR) | It can keep constant output voltage automatically when the mains voltage | |||
Overvoltage/overcurrent stall control | The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to over voltage/over current | |||
Rapid current limit | It helps to avoid frequent over current faults of the AC drive. | |||
Torque limit and control | It can limit the torque automatically and prevent frequent over current tripping during the running process. Torque control can be | |||
implemented in the FVC mode. | ||||
Support for multiple PG card | Support for differential input PG card, resolver PG card ,rotating transformer PG card |
T9000 inverter Model | Input Voltage (V) | Rated output power(kW) | Rated input current(A) | Rated output current(A) | Motor Power (KW) |
T9400-0R4G | 3PH AC 380V±15% | 0.4 | 3.4 | 1.2 | 0.4 |
T9400-0R75G | 0.75 | 3.8 | 2.5 | 0.75 | |
T9400-1R5G | 1.5 | 5 | 3.7 | 1.5 |
Q: The inverter's keypad is detachable?
A: Yes
Q: What is your inverter's control mode?
A: This T9000 series inverter have V/F control, close loop vector control, and open loop vector control.
Q: What is the communication of this series of inverter support?
A: Profinet and standard RS485.
Q: Does this series of inverter have 24V terminal?
A: Yes.