The Z5000-BF series inverter offers a multitude of benefits. It provides exceptional performance and boasts a minimal failure rate, guaranteeing dependable operation. With its superior waterproof and dustproof capabilities, it is perfectly suited for demanding environments. Moreover, the Z5000-BF series is energy-efficient, contributing to reduced power consumption. Additionally, it incorporates effective heat dissipation mechanisms and a straightforward installation process. Overall, the Z5000-BF series inverter excels in terms of performance, reliability, water and dust resistance, energy efficiency, heat dissipation, and ease of installation.
Item | Z5000-BF inverter |
Control Mode | Sensorless flux vector control(SFVC) Voltage/Frequency (V/F) Control |
Maximum frequency | Vector control:0-320Hz V/F control:0-3200Hz |
Carrier frequency | 1kHz~16kHz The carrier frequency is automatically adjusted based on the load features. |
Input frequency resolution | Digital setting:0.01Hz Analog setting: Maximum frequency 0.025% |
Start torque | G: Type:0.5Hz/150%(SVC) P: Type:0.5Hz/100% |
Speed range | 1:100(SVC) |
Speed stability accuracy | ±0.5%(SVC) |
Overload capacity | G Type:60s for 150% of the rated current, 3s for 180% of the rated current. P Type:60s for 120% of the rated current, 3s for 150% of the rated current. |
Torque boost | Auto-boost ; Customized boost:0.1%~30.0% |
VF curve | Line V/F curve;Multi-point V/F curve;N-power V/F curve |
VF separation | 2 types: complete separation;half separation |
Ramp Mode | Straight-line ramp;S-curve ramp;Four groups of acceleration/deceleration time:0~6500.0s |
Auto voltage regulation(AVR) | It can keep constant output voltage automatically when the mains voltage changes |
Rapid current limit | It helps to avoid frequent over current faults of the AC drive. |
Torque limit and control | It can keep constant output voltage automatically when the mains voltage changes |
Onboard PID | It realizes process-controlled closed loop control system easily |
JOG control | JOG frequency range: 0.00–50.00 Hz JOG acceleration/deceleration time: 0.0–6500.0s |
DC braking | DC braking frequency:0.00Hz to maximum frequency Braking time:0.0-100.0s Braking action current value:0.0%-100.0% |
Instantaneous blackout doesn’t stop | The load feedback energy compensates the voltage reduction so that the AC drive can continue to run for a short time. |
Timing control | Timing range:0.0Min~6500.0Min |
Communication | RS485 |
Run command channel | Given by the panel,control terminals,serial communication port,can be switched by many ways |
Frequency source | 10 kinds of frequency source, given by digital analog voltage, analog current, pulse, serial port. It can be switched by many ways |
Auxiliary frequency source | 10 kinds of frequency source, can easily realize micro adjustment, frequency Synthesizer |
Input terminals | 6 digital input terminals, one of which supports up to100 kHz high-speed pulse input (optional). 2 analog input terminal, one of which only supports0-10 V voltage input and the other supports 0-10V voltage input or 4-20 mA current input. |
Output terminals | 1 digital output terminal 1 relay output terminal 1 analog output terminal: that supports 0-20 mA current output or 0-10v voltage output |
Multiple protection modes | Motor short-circuit detection at power-on, output phase loss protection, over-current protection, over-voltage protection, under voltage protection, overheat protection and overload protection. |
Model | Rated output power (kW) | Rated input current (A) | Rated output current (A) | Motor Power (kW) |
Input voltage(v):1PH AC 220V±15% | ||||
Z5200A0D75K-BF | 0.75 | 7.2 | 5 | 0.75 |
Z5200A01D5K-BF | 1.5 | 10 | 7 | 1.5 |
Z5200A02D2K-BF | 2.2 | 16 | 11 | 2.2 |
Input voltage(v):3PH AC 380V±15% | ||||
Z5400A0D75K-BF | 0.75 | 3.8 | 2.5 | 0.75 |
Z5400A01D5K-BF | 1.5 | 5 | 3.7 | 1.5 |
Z5400A02D2K-BF | 2.2 | 5.8 | 5 | 2.2 |
Z5400A03D7K-BF | 3.7 | 10 | 9 | 3.7 |
Z5400A05D5K-BF | 5.5 | 15 | 13 | 5.5 |
Z5400A07D5K-BF | 7.5 | 20 | 17 | 7.5 |
Z5400A0011K-BF | 11 | 26 | 25 | 11 |
Z5400A0015K-BF | 15 | 35 | 32 | 15 |
Z5400A0018K-BF | 18 | 38 | 37 | 18 |
Z5400A0022K-BF | 22 | 46 | 45 | 22 |
Z5400A0030K-BF | 30 | 62 | 60 | 30 |
Z5400A0037K-BF | 37 | 76 | 75 | 37 |
Z5400A0045K-BF | 45 | 92 | 90 | 45 |
Z5400A0055K-BF | 55 | 113 | 110 | 55 |
Z5400A0075K-F | 75 | 157 | 150 | 75 |
Z5400A0090K-BF | 90 | 180 | 176 | 90 |
Z5400A0110K-BF | 110 | 214 | 210 | 110 |
Z5400A0132K-BF | 132 | 256 | 253 | 132 |
Z5400A0160K-BF | 160 | 307 | 300 | 160 |
Model | Motor | Output Current | Mounting dimension(mm) | |||||
Overall dimension | ||||||||
W | H | D | A | B | Φd | |||
Z5200A0D75K-BF | 0.75 | 5 |
188 |
122 |
134 |
178 |
105 |
4 |
Z5200A01D5K-BF | 1.5 | 7 | ||||||
Z5200A02D2K-BF | 2.2 | 11 | ||||||
Z5400A0D75K-BF | 0.75 | 2.5 | ||||||
Z5400A01D5K-BF | 1.5 | 3.7 | ||||||
Z5400A02D2K-BF | 2.2 | 5 | ||||||
Z5400A03D7K-BF | 3.7 | 9 |
235 |
154 |
179 |
225 |
129 |
4 |
Z5400A05D5K-BF | 5.5 | 13 | ||||||
Z5400A07D5K-BF | 7.5 | 17 | ||||||
Z5400A0011K-BF | 11 | 25 | ||||||
Z5400A0D75K-BF-V | 0.75 | 2.5 |
140 |
190 |
138 |
130 |
160 |
4.5 |
Z5400A01D5K-BF-V | 1.5 | 3.7 | ||||||
Z5400A02D2K-BF-V | 2.2 | 5 | ||||||
Z5400A03D7K-BF-V | 3.7 | 9 |
192 |
280 |
178 |
180 |
200 |
5.5 |
Z5400A05D5K-BF-V | 5.5 | 13 | ||||||
Z5400A07D5K-BF-V | 7.5 | 17 | ||||||
Z5400A0011K-BF-V | 11 | 25 | ||||||
Z5400A0015K-BF | 15 | 32 | ||||||
Z5400A0018K-BF | 18 | 37 | 236 | 300 | 204 | 225 | 250 | 7 |
Z5400A0022K-BF | 22 | 45 | ||||||
Z5400A0030K-BF | 30 | 60 | 236 | 400 | 231 | 225 | 175+175 | 7 |
Z5400A0037K-BF | 37 | 75 |
Note:
380v/0.75-11kw Horizontal installation and vertical installation exist at the same time. -V indicates vertical installation. Above 15kw is installed vertically.
Application:
The Z5000-BF series drives are ideal for use in high-pollution, high-humidity environments, with excellent water resistance to prevent inverter damage.
First of all, the Z5000-BF series inverter uses a highly protective housing design, which effectively prevents moisture, dust and other contaminants from entering the interior. This design enables the inverter to work normally in a highly polluted environment without interference from the external environment.
Secondly, the Z5000-BF series inverter uses professional waterproof technology to ensure its reliability in high humidity environments. It has a waterproof sealing structure and waterproof wiring design to effectively prevent moisture penetration into key components and reduce the risk of damage. Whether in wet factory floors, water treatment plants or outdoor environments, the Z5000-BF series drives work stably and protect equipment from moisture.
In addition, the Z5000-BF series drives undergo rigorous protection testing and quality control to ensure their reliability and durability in harsh environments. It has good moisture resistance and corrosion resistance, can withstand the challenges brought by high humidity environment, and extend the service life.
In short, the Z5000-BF series inverter is the ideal choice for use in high pollution and high humidity environments. Its waterproof performance and reliability enable it to protect the inverter from damage in harsh environments and ensure the stable operation of the equipment. Whether in industrial production, water treatment, mines or other high humidity environments, the Z5000-BF series drives provide reliable electric drive solutions.
Typical Wiring diagram:
1:What is your MOQ?
1 PC.
2:What is terms of payment?
T/T 100% before delivery.
3:What is your delivery time?
Fast delivery is our advantage. Usually within ten days.
4:How can we do OEM/ODM?
We do OEM for more than 40 brands. If your order reaches a certain quantity, we can do it for you.