1: Synchronous and asynchronous motor open-loop/closed-loop vector control, V/F control (with built-in PID).
2: Large torque output to ensure smooth motor start under heavy load.
3: Powerful function, outstanding performance, suitable for most general occasions.
4:Supports various types of PG cards.
5:Supports instant stop and instant start.
6:It is compact and easy for customers to install.
7: The voltage range is 220v,380v,415v,440v,460v, and the maximum power is 450kw.
Item | T9000 series inverter | |
Basic function | Control mode | V/F control Open loop vector control (without PG); Closed loop vector control (with PG). |
Maximum frequency | 0.00-600.00Hz. | |
Carrier frequency | 0.5kHz~16kHz The carrier frequency is automatically adjusted based on the load features. | |
Input frequency resolution | Digital setting:0.01Hz Analog setting: Maximum frequency 0.025% | |
Start torque | G-type:0.5Hz/150%(no PG); P-type :0.5Hz/100% | |
Speed range | 1:100(No PG) | |
Speed stability accuracy | ±0.5%(No PG) | |
Basic function | Overload capacity | G Type:60s for 150% of the rated current, 3s for 180% of the rated current. P Type:60s for 120% of the rated current, 3s for 150% of the rated current. |
Torque boost | Auto-boost ; Customized boost:0.1%~30.0%. | |
VF curve | Straight-line VF curve; Multi-point VF curve; N-power VF curve(1.2 power, 1.4 power, 1.6 power, 1.8 power, 2 power) | |
VF separation | 2 types: complete separation;half separation. | |
Ramp Mode | Linear or S-curve acceleration and deceleration mode. Four kinds of acceleration and deceleration time, acceleration and deceleration time range 0.0~65000s. | |
DC braking | Dc braking frequency :0.00Hz~ maximum frequency;Braking interval :0.0s~36.0s ;Braking action current value :0.0%~100.0% | |
JOG control | Jog frequency range:0~50Hz Jog acceleration/deceleration time:0-6500s | |
Simple PLC; Multi-speed operation | Up to 16 segment speeds are possible with built-in PLC or control terminals. | |
Built-in PID | It is convenient to realize the closed-loop control system of process control. | |
Automatic Voltage Regulation (AVR) | When the grid voltage changes, it can automatically keep the output voltage constant. | |
Overvoltage and overcurrent stall control | Automatic current and voltage limit during operation to prevent frequent overvoltage skipping. | |
Rapid current limiting function | Minimize the overcurrent fault and protect the normal operation of the inverter. | |
Torque limit and control | Automatic torque limit during operation to prevent frequent overcurrent tripping; The closed-loop vector mode enables torque control. | |
Characteristic function | Excellent performance | The control of asynchronous motor is realized with high performance current vector control technology. |
Instant stop non-stop function | The load feedback energy is used to compensate the voltage reduction in the transient power failure, and the inverter can continue to run for a short time. | |
Rapid current limit | It helps to avoid frequent over current faults ofthe AC drive. | |
Timing control | Timing range:00Min-6500.0Min. | |
Communication | Modbus RS485;Profinet communication(Optional communication card). | |
Supports a variety of PG cards | Support for differential input PG card, resolver PG card, rotating transformer PG card and so on. | |
Running | Command source | Operation panel, control terminal, serial communication port. Users can switch in a variety of ways. |
Frequency source | 10 frequency sources: digital set, analog voltage set, analog current set, pulse set, serial port set. Users can switch in a variety of ways. | |
Auxiliary frequency source | 10 auxiliary frequency sources. Users can flexibly realize auxiliary frequency fine-tuning and frequency synthesis. | |
Input terminal | Standard :4(1PH 220V 0.4kW-2.2kW-VF control) / 5(1PH 220V 0.4kW-3.7kW-vector control /3PH 380V 0.4kW-5.5kW vector control) / 6(7.5kW or more) digital input terminals, The S3 supports high-speed pulse input up to 100kHz; 1 (below 5.5KW) / 2 (above 7.5KW) analog input terminals, 1 support 0-10V voltage input, 1 (above 7.5KW) support 0-10V voltage input or 4-20mA current input. | |
Output terminal | 1 high-speed pulse output and collector output terminals (1PH 220V 0.4KW-2.2KW-VF control is not supported); 1(below 5.5KW)/2(above 7.5KW) relay output terminal; 1(1PH 220V 0.4kW-3.7kw-vector /3PH 380V 0.4KW-5.5KW vector)/ 2(7.5KW or more) mode output terminal, support 4~20mA current output or 0~10V voltage output. | |
Protection | Protection function | Short-circuit detection, input and output phase loss protection, overcurrent protection, overvoltage protection, undervoltage protection, overheat protection, overload protection, etc. |
Service | OEM/ODM services | We offer this service to customers in many countries around the world, and we recruit distributors worldwide. |
Warranty | We provide 18 months of failure replacement, free maintenance and other services. |
T9000 Series | |||
Vector/VF control | Yes | Closed loop vector control | Yes |
Built-in brake unit | Support below 37kw. Above 45kw optional | 0.1s acceleration and deceleration | Yes |
Removable panel | Support below 5.5kw | High speed pulse output | Yes |
24v power supply | Yes | DC braking | Yes |
STO function | Yes | Profinet / RS485 | Yes |
I/O extension | Yes | External set filter | Yes |
External brake resistor | Yes | Simple PLC function | Yes |
Electric reactor | Optional | PID | Yes |
EMC filter | No | Level of protection | IP20 |
Safety certificate | CE | Simple PLC function | Yes |
Collector | 1 | Multi-protection | Yes |
Model | Rated output power (kW) | Rated input current (A) | Rated output current (A) | Motor Power (kW) |
Input voltage(v):1PH/3PH AC 220V±15% | ||||
T9200-0R4G | 0.4 | 5.4 | 2.5 | 0.4 |
T9200-0R75G | 0.75 | 7.2 | 5 | 0.75 |
T9200-1R5G | 1.5 | 10 | 7 | 1.5 |
T9200-2R2G | 2.2 | 16 | 11 | 2.2 |
T9200-3R7G | 3.7 | 17 | 16.5 | 3.7 |
T9200-5R5G | 5.5 | 26 | 25 | 5.5 |
T9200-7R5G | 7.5 | 35 | 32 | 7.5 |
Input voltage(v):3PH AC 380V±15% | ||||
T9400-0R4G | 0.4 | 3.4 | 1.2 | 0.4 |
T9400-0R75G | 0.75 | 3.8 | 2.5 | 0.75 |
T9400-1R5G | 1.5 | 5 | 3.7 | 1.5 |
T9400-2R2G | 2.2 | 5.8 | 5 | 2.2 |
T9400-3R7G/5R5P | 3.7/5.5 | 10/15 | 9/13 | 3.7/5.5 |
T9400-5R5G/7R5P | 5.5/7.5 | 15/20 | 13/17 | 5.5/7.5 |
T9400-7R5G/11P | 7.5/11 | 20/26 | 17/25 | 7.5/11 |
T9400-11G/15P | 11/15 | 26/35 | 25/32 | 11/15 |
T9400-15G/18.5P | 15/18.5 | 35/38 | 32/37 | 15/18.5 |
T9400-18.5G/22P | 18.5/22 | 38/46 | 37/45 | 18.5/22 |
T9400-22G/30P | 22/30 | 46/62 | 45/60 | 22/30 |
T9400-30G/37P | 30/37 | 62Z76 | 60/75 | 30/37 |
T9400-37G/45P | 37/45 | 76/90 | 75/90 | 37/45 |
T9400-45G/55P | 45/55 | 92/113 | 90/110 | 45/55 |
T9400-55G | 55 | 113 | 110 | 55 |
T9400-75P | 75 | 157 | 150 | 75 |
T9400-75G/90P | 75/90 | 157/180 | 150/176 | 75/90 |
T9400-90G/110P | 90/110 | 180/214 | 176/210 | 90/110 |
T9000 series inverter has been widely used in the fountain industry, and has achieved good results. This series of inverter adopts advanced technology and reliable design to meet the needs of electric drive in fountain systems.
First of all, the T9000 series inverter has precise control capabilities. It can precisely adjust the operating frequency and speed of equipment such as pumps, sprinklers and lights according to the needs of the fountain. This can achieve a variety of fountain effects, such as water spray height, water spray shape and lighting changes, to meet the needs of different scenes.
Secondly, the T9000 series inverter has stable and reliable performance. It uses high-quality components and reliable circuit design to maintain stable performance over long periods of operation. The fountain system usually needs to run for a long time, so the reliability of the inverter is required. The T9000 series inverter can work stably to ensure the continuous operation of the fountain system.
In addition, the T9000 series inverter also has the characteristics of intelligence. It can be programmed and set to achieve automatic control and intelligent management. Users can set different working modes and time plans according to their needs to achieve automatic switching, timed start and other functions to improve the operating efficiency and energy saving effect of the fountain system.
In short, the T9000 series inverter has shown excellent application results in the fountain industry. Its precise control, stable reliability and intelligent characteristics make it an ideal choice for fountain systems. Whether in parks, squares, hotels or scenic spots, the T9000 series inverter can provide reliable and efficient electric drive for the fountain system, creating beautiful and spectacular fountain effects.
Q1:What is your MOQ?
A: 1 pc
Q2:What's your terms of payment?
A:T/T 100% before delivery.
Q3:What's your delivery time?
A:Generally within 15 days after receiving full payment.
Q4:How can l get OEM/ODM order?
A:If your order quantity meets certain requirements, we are happy to customize it for you. We have cooperation with more than forty manufacturers.