The T200 series inverter is a leader in the field of industrial automation and has won widespread praise in the global market for its outstanding performance and comprehensive features. This inverter is not only a technological breakthrough, but also performs well in many industrial applications with its stability and high efficiency. The T200 series inverter has been exported to countries all over the world and has become an indispensable partner in many industrial fields, including but not limited to pumps, food processing machinery, textile machinery, etc. Its precise control capabilities and flexible configuration options ensure reliable operation in a variety of complex working conditions, meeting the needs of different industries for high efficiency and high precision. The wide application of T200 series inverter not only improves production efficiency, but also reduces energy consumption, creating significant economic benefits for users.
Item | T200 technical parameters |
Maximum frequency | Vector control:0~600Hz V/F control:0~3200Hz |
Control mode | V/F control;Senseless flux vector control(SFVC); Closed loop vector control (CLVC) |
Carrier frequency | 0.5kHz~16kHz The carrier frequency can be automatically adjusted based on the load feature |
Input frequency resolution | Digital setting:0.01Hz Analog setting: maximum frequency×0.025% |
Startup torque | G Type:0.5Hz/150%(SFVC); P Type:0.5Hz/100% |
Speed range | 1:100(No PG) |
Speed stability accuracy | ±0.5%(No PG) |
Torque control accuracy | ±5%(FVC) |
Overload capacity | G type: 60s for 150% of the rated current, 3s for 180% of the rated current P type: 60s for 120% of the rated current, 3s for 150% of the rated current |
Torque boost | Fixed boost;Customized boost 0.1%-30.0% |
V/F curve | Straight-line V/F curve;Multi-point V/F curve; N-power V/F curve (1.2-power, 1.4-power, 1.6- power,1.8-power, square) |
V/F separation | Two types: complete separation; half separation |
Ramp mode | Straight-line ramp;S-curve ramp Four groups of acceleration/deceleration time with the range of 0.00-6500.0s |
DC braking | DC braking frequency: 0.00 Hz to maximum frequency Braking time: 0.0-100.0s Braking action current value: 0.0%–100.0% |
JOG control | Jog frequency range:0.00Hz~50.00Hz. Jog acceleration/deceleration time0.0s~6500.0s |
Onboard multiple preset speeds | It implements up to 16 speeds via the simple PLC function or by input terminal state |
Onboard PID | It realizes process-controlled closed loop control system easily |
Auto voltage regulation (AVR) | It can keep constant output voltage automatically when the mains voltage changes |
Over-voltage/Over-current stall control | The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to over-voltage/over-current. |
Rapid current limit | It helps to avoid frequent over-current faults of the inverter |
Torque limit and torque control | It can limit the torque automatically and prevent frequent over-current tripping during the running process |
High performance | Control of asynchronous motor is implemented through the high-performance current vector control technology |
Instantaneous stop doesn’t stop | The load feedback energy compensates the voltage reduction so that the AC drive can continue to run for a short time |
Timing control | Timing range 0.0Min~6500.0Min |
Communication methods | RS485;EtherCAT;Profibus-DP;CAN is optional |
Protection mode | Motor short-circuit detection at power-on, input output phase loss protection, over-current protection, over-voltage protection, under voltage protection, overheat protection and overload protection. |
Key locking and function selection | It can lock the keys partially or completely and define the function range of some keys so as to prevent mis-function. |
Running command channel | Given by the panel, control terminals, Serial communication port, can be switched by many ways |
Frequency source | 10 kinds of frequency source, given by digital analog voltage, analog current, pulse, serial port. can be switched by many ways |
Auxiliary frequency source | There are ten auxiliary frequency sources. It can implement fine tuning of auxiliary frequency and frequency synthesis |
Input terminals | 5 digital input terminals, one of which supports up to 100 kHz high-speed pulse input; 1 analog input terminal, supports 0-10V voltage input or 4–20 mA current input. |
Output terminals | 1 digital output terminal 1 relay output terminal 1 analog output terminal : that supports 0–20 mA current output or 0–10 V voltage output |
Key locking and function selection | It can lock the keys partially or completely and define the function range of some keys so as to prevent mis-function. |
Protection mode | Motor short-circuit detection at power-on, input output phase loss protection, over-current protection, over-voltage protection, under voltage protection, overheat protection and overload protection. |
Model | Input voltage | Rated output power(kw) | Rated input current(A) | Rated output current(A) | Motor power(kw) |
T200-0R4G-2 | AC 1PH 220V± 15% | 0.4 | 5.4 | 2.5 | 0.4 |
T200-0R75G-2 | 0.75 | 7.2 | 5.0 | 0.75 | |
T200-1R5G-2 | 1.5 | 10.0 | 7.0 | 1.5 | |
T200-2R2G-2 | 2.2 | 16.0 | 11.0 | 2.2 | |
T200-0R4G-4 | AC 3PH 380V±15% | 0.4 | 3.4 | 1.2 | 0.4 |
T200-0R75G-4 | 0.75 | 3.8 | 2.5 | 0.75 | |
T200-1R5G-4 | 1.5 | 5.0 | 3.7 | 1.5 | |
T200-2R2G-4 | 2.2 | 5.8 | 5.0 | 2.2 | |
T200-3R0G-4 | 3.0 | 8.5 | 7.0 | 3.0 | |
T200-3R7G/5R5P-4 | 3.7/5.5 | 10/15 | 9/13 | 3.7/5.5 | |
T200-5R5G/7R5P-4 | 5.5/7.5 | 15/20 | 13/17 | 5.5/7.5 | |
T200-7R5G/11P-4 | 7.5/11 | 20/26 | 17/25 | 7.5/11 | |
T200-11G/15P-4 | 11/15 | 26/35 | 25/32 | 11/15 | |
T200-15G/18.5P-4 | 15/18.5 | 35/38 | 32/37 | 15/18.5 | |
T200-18.5G/22P-4 | 18.5/22 | 38/46 | 37/45 | 18.5/22 | |
T200-22G/30P-4 | 22/30 | 46/62 | 45/60 | 22/30 | |
T200-30G/37P-4 | 30/37 | 62/76 | 60/75 | 30/37 | |
T200-37G/45P-4 | 37/45 | 76/90 | 75/90 | 37/45 | |
T200-45G/55P-4 | 45/55 | 92/113 | 90/110 | 45/55 | |
T200-55G/75P-4 | 55/75 | 113/157 | 110/152 | 55/75 |
No. | Expansion card model | PCB internal model number | Function description | Applicable model |
1 | PG-T11-01 | T11PG01 | ABZ_ Differential input PG card _5V | T200-0.4-55 kw |
2 | PG-T11-02 | T11PG02 | ABZ_OC& Push-pull input PG card _24V | |
3 | ET-T11-01 | T11JK01 | 1 normally open normally closed relay 2 DL_1 FIV_1 FOC | |
4 | ET-T11-02 | T11JK02 | 1 high speed pulse output _2 DI_1 FIV_1 FOC | |
5 | CM-T11-01 | T11CM01 | ProfibusDP communication card | |
6 | CM-T11-02 | T11CM02 | Ethercat communication card | |
7 | CM-T11-03 | T11CM03 | CAN communication card | |
8 | CM-T11-04 | T11CM04 | Modbus TCP communication card | |
9 | CM-T11-05 | T11CM05 | Profinet communication card | |
Note: This model only has 1 multi-function expansion card interface, communication card and PG share this interface Communication card and PG card can only select one extension, not compatible at the same time. |
ZONCN T200 series inverter is a high efficiency inverter designed for the industrial field, widely used in fans, pumps, lathes, compressors, textile equipment and other industrial equipment. With its superior performance and reliability, the T200 series drives are favored by consumers.ZONCN T200 series inverter with its excellent performance, easy operation and low failure rate, is the ideal choice for fans, pumps, lathes, compressors, textile equipment and other equipment in the industrial field. Whether it is the matching of new equipment or the upgrading of old equipment, the T200 series inverter can provide a reliable and economical solution.
Q2:What's your terms of payment?
A:T/T 100% before delivery.
Q3:What's your delivery time?
A:Generally within 15 days after receiving full payment.
Q4:How can l get OEM/ODM order?
A:If your order quantity meets certain requirements, we are happy to customize it for you. We have cooperation with more than forty manufacturers.