High Protection IP65 IP54 Inverter VFD 220v 380v Variable Frequency Inverter For Pump
ITEM | Z5000-BF Series VFD Inverter | |
Standard functions | Control mode | Sensorless flux vector control (SFVC) |
Voltage/Frequency (V/F) control | ||
Maximum frequency | Vector control: 0–320 Hz | |
V/F control: 0–3200Hz | ||
Carrier frequency | 1 kHz–16 kHz | |
The carrier frequency can be automatically adjusted based on the load features. | ||
Input frequency resolution | Digital setting: 0.01 Hz | |
Analog setting: maximum frequency x 0.025% | ||
Startup torque | G type: 0.5 Hz/150% (SFVC); | |
P type: 0.5 Hz/100% | ||
Speed range | 1:100 (SFVC) | |
Speed stability accuracy | ± 0.5% (SFVC) | |
Overload capacity | G type: 60s for 150% of the rated current, 3s for 180% of the rated current. | |
P type: 60s for 120% of the rated current, 3s for 150% of the rated current | ||
Torque boost | Fixed boost | |
Customized boost 0.1%–30.0% | ||
V/F curve | Straight-line V/F curve | |
Multi-point V/F curve | ||
N-power V/F curve (1.2-power, 1.4-power, 1.6-power, 1.8-power, square) | ||
V/F separation | Two types: complete separation; half separation | |
Ramp mode | Straight-line ramp | |
S-curve ramp | ||
Four groups of acceleration/deceleration time with the range of 0.0–6500.0s | ||
DC braking | DC braking frequency: 0.00 Hz to maximum frequency; Braking time: 0.0-36.0s; | |
Braking action current value: 0.0%–100.0% | ||
JOG control | JOG frequency range: 0.00–50.00 Hz | |
JOG acceleration/deceleration time: 0.0–6500.0s | ||
Onboard Multiple preset speeds | It implements up to 16 speeds via the simple PLC function or by input(X) terminal states | |
Onboard PID | It realizes process-controlled closed loop control system easily. | |
Auto voltage | It can keep constant output voltage automatically when the mains voltage changes. | |
regulation (AVR) | ||
Over-voltage/ | The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to over-voltage/over-current. | |
Over-current stall | ||
control | ||
Torque limit and torque control | It can limit the torque automatically and prevent frequent over-current tripping during the running process. | |
Instantaneous stop doesn’t stop | The load feedback energy compensates the voltage reduction so that the AC drive can continue to run for a short time. | |
Rapid current limit | It helps to avoid frequent over-current faults of the AC drive. | |
High performance | Control of asynchronous motor is implemented through the high-performance current vector control technology. | |
Timing control | Time range: 0.0–6500.0 minutes | |
Communication methods | RS485 | |
Running command channel | Given by the panel, control terminals, | |
Serial communication port, can be switched by many ways | ||
Frequency source | 10 kinds of frequency source, given by | |
Digital analog voltage, analog current, Pulse, serial port. can be switched by many ways | ||
Auxiliary frequency source | 10 kinds of Frequency source, given by Digital analog voltage, analog current, pulse, serial port. Can be switched by many ways. | |
Input and output | Input terminals | 6 digital input terminals, one of which supports up to 100 kHz high-speed pulse input.(S3) |
2 analog input terminal,one of which only supports 0-10V voltage input and the other supports 0–10 V voltage input and 4–20 mA current input. | ||
Output terminal | 1 digital output terminal | |
1 relay output terminal (RA.RB.RC) | ||
1 analog output terminal :that supports 0–20 mA current output or 0–10 V voltage output | ||
Frequency source | Digital setting, analog voltage setting, analog current setting, pulse setting and serial communication port setting. | |
LED display | It displays the parameters. | |
Key locking and function selection | It can lock the keys partially or completely and define the function range of some keys so as to prevent malfunction. | |
Protection mode | Motor short-circuit detection at power-on, output phase loss protection, over-current protection, over-voltage protection, under voltage protection, overheat protection and overload protection. |
VFD Model | Input voltage | Rated Output Power (KW) | Rated Input current (A) | Rated Output Current (A) | Motor Power (kW) |
Z5200A00D7K-BF | 1PH AC220V ±15% | 0.75 | 7.2 | 5 | 0.75 |
Z5200A01D5K-BF | 1.5 | 10 | 7 | 1.5 | |
Z5200A02D2K-BF | 2.2 | 16 | 11 | 2.2 | |
Z5400A0D75K-BF | 3PH AC380V ±15% | 0.75 | 3.8 | 2.5 | 0.75 |
Z5400A1D5K-BF | 1.5 | 5 | 3.7 | 1.5 | |
Z5400A02D2K-BF | 2.2 | 5.8 | 5 | 2.2 | |
Z5400A03D7K-BF | 3.7 | 10 | 9 | 3.7 | |
Z5400A05D5K-BF | 5.5 | 15 | 13 | 5.5 | |
Z5400A07D5K-BF | 7.5 | 20 | 17 | 7.5 | |
Z5400A0011K-BF | 11 | 26 | 25 | 11 | |
Z5400A0015K-BF | 15 | 35 | 32 | 15 | |
Z5400A0018K-BF | 18.5 | 38 | 37 | 18.5 | |
Z5400A0022K-BF | 22 | 46 | 45 | 22 | |
Z5400A0030K-BF | 30 | 62 | 60 | 30 | |
Z5400A0037K-BF | 37 | 76 | 75 | 37 | |
… | … | … | … | … | |
Z5400A00160K-BF | 160 | 160 |