Automatic Zone Heating valves with manual handle, brass two way electric ball valve
Product Description
The stainless steel / brass zone valves is a type of controls zone valves, which control the flow of water to a given zone in a hydronic heating system. The zone heating valves can be used in a variety of applications, including radiant and hydronic heating. It creats multiple zones improves efficiency and occupant comfort in a home.
Features
1. Extreme long service life span ;
2. Manual Override, the valve can be operated when power failure;
3. Mini dimension and position indicator;
4. Good sealing performance, IP65 enclosure.
Application
Advantages
No. | Ours | Normal products |
Valve shaft seal | Quadruple seals | Dual seals |
Nut seal | Auto super anaerobic glue coating, Consistent torque tightening | Manual anaerobic glue, unevenly, non consistent torque tightening |
Seal between valve body and housing | Seal groove | none |
Torque | Smoothly and light | Heavy, non consistently |
Drainage | Yes | none |
Technical data
Model | 25S |
Work Current (mA) | <80 |
Protection | IP65 |
Power (W) | <2 |
Operate pressure (Mpa) | PN10 |
Torque (NM) | 2.5 |
Diameter range (mm) | DN8-DN32 two way DN8-DN20 three way |
Open/close time (S) | <8 |
Work voltage (V) | DC3-6V; DC12V; AC/DC9-24V; AC220V; AC85-265V |
Liquid temperature (℃) | 0-90 |
Control mode | CR01; CR02; CR03; CR04; CR05 |
Valve body material | Connection port | Diameter | D | L | H | W |
(mm) | (Kg) | |||||
Brass | Both female thread full diameter | DN8 | 8 | 46 | 31 | 0.357 |
DN15 | 15 | 57 | 38 | 0.433 | ||
DN20 | 20 | 71 | 45 | 0.513 | ||
DN25 | 23.5 | 72 | 49 | 0.603 | ||
Both female threaded reduced diameter | DN10 | 8 | 46 | 31 | 0.356 | |
DN20 | 15 | 66 | 38 | 0.448 | ||
DN25 | 20 | 72 | 47 | 0.608 | ||
DN32 | 25 | 86 | 60 | 0.82 | ||
3-way vertical | DN15 | 12 | 63 | 49 | 0.434 | |
DN20 | 15 | 66 | 53 | 0.492 | ||
Female-male thread full port | DN15 | 15 | 63 | 38 | 0.432 | |
Female-male thread reduce port | DN20 | 15 | 66 | 38 | 0.462 | |
Both male thread | DN15 | 15 | 68 | 38 | 0.424 | |
Stainless steel | Both female thread full diameter | DN8 | 8 | 46 | 31 | 0.364 |
DN15 | 15 | 55 | 38 | 0.44 | ||
DN20 | 20 | 71 | 45 | 0.508 | ||
DN25 | 25 | 72 | 49 | 0.617 | ||
Both female threaded reduce diameter | DN15 | 8 | 46 | 30.5 | 0.368 | |
DN20 | 15 | 63 | 39 | 0.513 | ||
DN25 | 20 | 75 | 47 | 0.608 |
Wiring options
1. Connecting SW to OPEN , the valve opens , getting the position ,automatically power off, the valve remain fully open position
2. Connection SW to CLOSE , the valve close , getting the position ,automatically power off, the valve remains side passes position(fully closed)
1. Connecting SW to OPEN, the valve opens , getting the position ,automatically power off, the valve remain fully open position
2. Connection SW to CLOSED, the valve close , getting the position ,automatically power off, the valve remains side passes position (fully closed)
Note: AC24V/AC220V can only be used for 50K series electric valves
1. Connecting SW, the valve opens , getting the position ,automatically power off, thevalve remain fully open position
2. Disconnecting SW, the valve close , getting the position ,automatically power off, the valve remains side passes position (fully closed)
Note: When power is DC voltage and Red Wires is “+”,Blue wire is “—”
1. SW connecting, the valve open, getting the position and the power off automatically, the valve remains fully open/close position
2. SW disconnecting, the valve close, getting the position and power off automatically, the valve remains fully open/close position
1. Connecting SW and OPEN, the valve opens, getting the position green wire output the OLS signal, the controller tests the signal OLS, connect SW to STOP, the valve stops and remains fully open position
2. Connecting SW and CLOSE, the valve close, getting the position red wire output the CLS signal, the controller tests the signal CLS, connect SW to STOP, the valve stops and remains fully close position,
Note: Please make sure the signal wires "red", "black" and "green" be connected at first, then connect the power wires " yellow" and "blue".
Factory show