Specifications
Brand Name :
Runpaq
Model Number :
8073-DRF01
Certification :
CE
Place of Origin :
China
MOQ :
50 pieces
Price :
USD25/piece (>1000pcs) / USD26.5 (50-1000 pcs)
Payment Terms :
L/C, T/T, D/A, D/P, Western Union
Supply Ability :
200000 sets/month
Delivery Time :
15-21 days
Packaging Details :
box + maste carton + pallet
Diameter :
DN8-20 (3 way ball valve)
Pressure :
10 bar / PN10 / 1.0 Mpa / 150 psi
Work current :
<80 mA
Voltage :
DC3-6V / DC12-24V / AC85-265V / AC230V
Power :
< 2W
Torque :
2.5 NM
Open/close time :
< 8 seconds
Product name :
underfloor heating valves control
Description

Zone valves, Brass 3 Way heating valves dN15, stainless water control valve for boiler

Product Description

A zone valve, can be 3 way heating valve, or 2 way straight heating valves, are installed on the hot side or boiler out side of the heating pipe loop, exposing the valve to higher and more stressful temperatures. The control ball valves installed backwards: the valve must be installed so that the arrow on the valve body to match the direction of flow of the hot water.

Features

1. Extreme ong service life span ;

2. Manual Override, the valve can be operated when power failure;

3. Mini dimension and position indicator

4. Good sealing performance, IP65 enclosure

Application

  • HVAC system heating, ventilation, air conditioning
  • Baseboard/radiant heating
  • Convectors
  • Fan coil units
  • Underfloor heating
  • Unit ventilators
  • VAV reheat

Advantages

  • Sturday valve body with reasonable structure design, and best material to be used
No. Ours Normal products
Valve shaft seal Quadruple seals Dual seals
Nut seal Auto super anaerobic glue coating, Consistent torque tightening Manual anaerobic glue, unevenly, non consistent torque tightening
Seal between valve body and housing Seal groove none
Torque Smoothly and light Heavy, non consistently
Drainage Yes none

Underfloor Boiler Zone Valve

Technical data

Model 20P-1.0B
Work Amp (mA) Max 80
Protection IP65
Power (W) <2
Operate Pressure (Mpa) PN10
Torque (NM) 2
Dia range DN8-32 (Straight); DN15-20 (Tee, three way)
Open/close (S) Straight: < 7s; Three way: <13s
Work volt. (V) DC3-6V, DC12V
Media temp (℃) 0-90
Control CR01, CR02, CR05
Dimensions
Underfloor Boiler Zone Valve
Valve body material Connection port Diameter D L H W
(mm) (Kg)
Brass Both female thread full diameter DN8 8 46 31 0.232
DN10 8 46 31 0.231
DN15 15 57 38 0.308
DN20 15 66 38 0.389
DN25 20 72 47 0.478
3-way vertical DN15 12 63 49 0.31
DN20 15 66 53 0.367
Female-male thread DN15 15 63 38 0.307
DN20 15 66 38 0.337
DN32 20 76 50 0.569
Both male thread DN15 15 68 38 0.299

Wiring options

  • Two wires and reverse polarity (DC3-6V / DC12V)

Underfloor Boiler Zone Valve

1.Connecting SW to OPEN , the valve opens , getting the position ,automatically power off, the valve remain fully open position

2.Connection SW to CLOSE , the valve close , getting the position ,automatically power off, the valve remains side passes position(fully closed)

  • Three wires and two control points (DC3-6V / DC12V / DC24V)

Underfloor Boiler Zone Valve

1.Connecting SW to OPEN, the valve opens , getting the position ,automatically power off, the valve remain fully open position

2.Connection SW to CLOSED, the valve close , getting the position ,automatically power off, the valve remains side passes position (fully closed)

Note:AC24V/AC220V can only be used for 50K series electric valves

  • Three wires and dual control point (DC3-6V/12V)

Underfloor Boiler Zone Valve

1.Connecting SW, the valve opens , getting the position ,automatically power off, thevalve remain fully open position

2.Disconnecting SW, the valve close , getting the position ,automatically power off, the valve remains side passes position (fully closed)

Note:When power is DC voltage and Red Wires is “+”,Blue wire is “—”

  • Two wires and power off return (DC3-6V/ADC9-24V/AC220V)

Underfloor Boiler Zone Valve

1.Connecting SW to OPEN, the valve opens, getting the position, automatically power off, the valve remains fully open position

2.Connecting SW to CLOSE, the valve close, getting the position and automatically power off, the valve remains fully close position

Note:AC24V/AC220V can only be used for 50K series electric valve

  • Five wires micro conntroller with signal feedback (DC3-6V/12V)

Underfloor Boiler Zone Valve

1.Connecting SW and OPEN, the valve opens, getting the position green wire output the OLS signal, the controller tests the signal OLS, connect SW to STOP, the valve stops and remains fully open position

2.Connecting SW and CLOSE, the valve close, getting the position red wire output the CLS signal, the controller tests the signal CLS, connect SW to STOP, the valve stops and remains fully close position,

Note:Please make sure the signal wires "red", "black" and "green" be connected at first, then connect the power wires " yellow" and "blue".

Send your message to this supplier
Send Now

Underfloor Boiler Zone Valve

Ask Latest Price
Brand Name :
Runpaq
Model Number :
8073-DRF01
Certification :
CE
Place of Origin :
China
MOQ :
50 pieces
Price :
USD25/piece (>1000pcs) / USD26.5 (50-1000 pcs)
Contact Supplier
Underfloor Boiler Zone Valve
Underfloor Boiler Zone Valve

Shanghai Runpaiq Technology Co., Ltd.

Active Member
5 Years
shanghai, shanghai
Since 2009
Business Type :
Manufacturer, Agent
Total Annual :
30000000-50000000
Employee Number :
100~200
Certification Level :
Active Member
Contact Supplier
Submit Requirement